{"product_id":"exazym®-streptaclick®-primer","title":"Exazym® StreptaClick® Primer","description":"\u003cdiv class=\"woocommerce-Tabs-panel woocommerce-Tabs-panel--description panel entry-content wc-tab\" id=\"tab-description\" role=\"tabpanel\" aria-labelledby=\"tab-title-description\"\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003cp class=\"p3\"\u003e\u003cb\u003eProduct Specification\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv class=\"product_description open\"\u003e\n\u003cp class=\"p1\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"s1\"\u003eproduct\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003econtains the streptavidin-oligo-dT primer required for polymerization of the DNA:RNA hybrid-ladder using the Exazym\u003cspan class=\"s2\"\u003e®\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePolymerase Reaction Kit. The reagent supplied is sufficient for at least one 96-well microplate. The\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"s1\"\u003eExazym\u003c\/span\u003e\u003cspan class=\"s3\"\u003e\u003cb\u003e®\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003esystem\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003ecan bring ultra-sensitive detection levels to conventional immunodiagnostic assays.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp class=\"p3\"\u003e\u003cb\u003eComponents\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li3\"\u003e\n\u003cp class=\"p1\"\u003e1 vial x 2.5 µg Exazym\u003cspan class=\"s1\"\u003e®\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003eStreptaClick\u003cspan class=\"s1\"\u003e®\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePrimer, 0.1 mg\/mL in TE buffer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp class=\"p3\"\u003e\u003cb\u003eShipping conditions\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p3\"\u003eShipped on wet ice.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMaterials and equipment required but not included\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p1\"\u003eExazym\u003cspan class=\"s1\"\u003e®\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePolymerase Reaction Kit 96 or 960\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eExazym\u003cspan class=\"s1\"\u003e®\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDetection Kit 96 or 960 (select the detection moiety appropriate for your assay; see options above)\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eExazym\u003cspan class=\"s1\"\u003e®\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWash Buffer, which is provided as blister tablets with Exazym\u003cspan class=\"s1\"\u003e®\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDetection Kit 96 and 960.\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eELISA diluent for dilution of Exazym\u003cspan class=\"s1\"\u003e®\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eStreptaClick\u003cspan class=\"s1\"\u003e®\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePrimer (e.g., PBS-based buffer at neutral pH containing stabilizer and detergent)\u003c\/li\u003e\n\u003cli class=\"p1\"\u003eAdhesive plate covers\u003c\/li\u003e\n\u003cli class=\"p1\"\u003ePlate washer; automated or manual (e.g., multi-pipette)\u003c\/li\u003e\n\u003cli class=\"p1\"\u003ePipettes and other standard laboratory equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p3\"\u003e\u003cb\u003eStorage conditions\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li3\"\u003e\n\u003cp class=\"p1\"\u003eExazym\u003cspan class=\"s1\"\u003e®\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003eStreptaClick\u003cspan class=\"s1\"\u003e®\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePrimer is stored at +2 °C to +8 °C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p5\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"woocommerce-Tabs-panel woocommerce-Tabs-panel--performance panel entry-content wc-tab\" id=\"tab-performance\" role=\"tabpanel\" aria-labelledby=\"tab-title-performance\"\u003e\n\u003ch3\u003e\u003cspan\u003ePerformance\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eExazym® StreptaClick® Primer (cat no. 10-0002-01) integrates BOLD signal amplification into any sandwich immunoassay that uses a biotinylated detector antibody. The data below illustrate typical resulting sensitivity gains on two commercial cytokine ELISAs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFigure 1\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cpicture\u003e\u003csource srcset=\"https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/002-1024x539.png.webp 1024w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/002-300x158.png.webp 300w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/002-768x404.png.webp 768w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/002-1536x808.png.webp 1536w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/002-600x316.png.webp 600w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/002.png.webp 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" type=\"image\/webp\"\u003e\u003cimg decoding=\"async\" class=\"aligncenter wp-image-26937 size-large\" src=\"https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/002-1024x539.png\" alt=\"\" width=\"1024\" height=\"539\" srcset=\"https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/002-1024x539.png 1024w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/002-300x158.png 300w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/002-768x404.png 768w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/002-1536x808.png 1536w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/002-600x316.png 600w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/002.png 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" data-eio=\"p\"\u003e\u003c\/picture\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cb\u003e\u003ci\u003eFigure 1. Standard curves and limit-of-detection improvement on two commercial assays. \u003c\/i\u003e\u003c\/b\u003e\u003ci\u003eUsing the optimized conditions, StreptaClick® Primer was applied to the R\u0026amp;D Systems Human IL-23 DuoSet (cat. DY1290, panel A) and the Mabtech Human IL-4 ELISA Flex (cat. 3410-1H-6, panel B). Both standard curves shifted markedly downward on the concentration axis, with LOD (signal-to-noise = 2) improving 11-fold for IL-23 and 16-fold for IL-4.\u003c\/i\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFigure 2\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cpicture\u003e\u003csource srcset=\"https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/Cytokine_poster_04_2026_v3-1-1024x908.png.webp 1024w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/Cytokine_poster_04_2026_v3-1-300x266.png.webp 300w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/Cytokine_poster_04_2026_v3-1-768x681.png.webp 768w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/Cytokine_poster_04_2026_v3-1-1536x1362.png.webp 1536w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/Cytokine_poster_04_2026_v3-1-600x532.png.webp 600w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/Cytokine_poster_04_2026_v3-1.png.webp 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" type=\"image\/webp\"\u003e\u003cimg loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-26934 size-large\" src=\"https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/Cytokine_poster_04_2026_v3-1-1024x908.png\" alt=\"\" width=\"1024\" height=\"908\" srcset=\"https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/Cytokine_poster_04_2026_v3-1-1024x908.png 1024w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/Cytokine_poster_04_2026_v3-1-300x266.png 300w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/Cytokine_poster_04_2026_v3-1-768x681.png 768w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/Cytokine_poster_04_2026_v3-1-1536x1362.png 1536w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/Cytokine_poster_04_2026_v3-1-600x532.png 600w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/Cytokine_poster_04_2026_v3-1.png 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" data-eio=\"p\"\u003e\u003c\/picture\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cb\u003e\u003ci\u003eFigure 2. In-assay optimization and resulting signal-to-noise ratio improvements. \u003c\/i\u003e\u003c\/b\u003e\u003ci\u003eThree dilutions of the biotinylated detector antibody were each combined with a high and a low concentration of StreptaClick® Primer; signal-to-noise was evaluated at the manufacturer’s lower specification limit (2 pg\/mL) and benchmarked against the unmodified standard ELISA. An 8-fold dilution of detector antibody combined with the higher StreptaClick® Primer concentration delivered the best low-end signal-to-noise ratio.\u003c\/i\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cpicture\u003e\u003csource srcset=\"https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/3.png.webp 577w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/3-300x31.png.webp 300w\" sizes=\"auto, (max-width: 577px) 100vw, 577px\" type=\"image\/webp\"\u003e\u003cimg loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-26919\" src=\"https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/3.png\" alt=\"\" width=\"577\" height=\"60\" srcset=\"https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/3.png 577w, https:\/\/cavidi.se\/wp-content\/uploads\/2026\/06\/3-300x31.png 300w\" sizes=\"auto, (max-width: 577px) 100vw, 577px\" data-eio=\"p\"\u003e\u003c\/picture\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe degree of sensitivity gain in any assay depends on the extent to which specific signal is amplified as compared to background noise— assays with low intrinsic background see the largest improvements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"woocommerce-Tabs-panel woocommerce-Tabs-panel--documents panel entry-content wc-tab\" id=\"tab-documents\" role=\"tabpanel\" aria-labelledby=\"tab-title-documents\"\u003e\u003c\/div\u003e","brand":"Cavidi","offers":[{"title":"Default Title","offer_id":52951879614688,"sku":"10-0002-01","price":0.0,"currency_code":"KRW","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/9330\/8896\/files\/Exazym_StreptaClick_Primer_product_image-2.jpg?v=1780538407","url":"https:\/\/rndmate.com\/products\/exazym%c2%ae-streptaclick%c2%ae-primer","provider":"알앤디메이트","version":"1.0","type":"link"}