{"product_id":"human-dvl1-segment-polarity-protein-dishevelled-homolog-dvl-1-elisa-kit-eh1769","title":"Human DVL1(Segment polarity protein dishevelled homolog DVL-1) ELISA Kit","description":"\u003cp\u003eIn your quest to understand DVL1, the segment polarity protein disheveled homolog DVL-1, rely on our Human DVL1 ELISA Kit (EH1769). This meticulously designed kit is engineered to provide accurate and efficient quantification of DVL1 levels in human samples, reinforcing data accuracy and trustworthiness.\u003cbr\u003e Uncompromising Precision: The EH1769 kit guarantees the highest level of precision and accuracy in quantifying DVL1, fortifying the reliability and integrity of your research data.\u003cbr\u003e Wide Detection Range: It accommodates a broad range of sample concentrations, making it suitable for diverse research applications.\u003cbr\u003e User-Friendly Interface: The kit simplifies laboratory procedures with clear and intuitive protocols, optimizing the research process and user experience.\u003cbr\u003e Efficiency in Time Management: Engineered for efficiency, it minimizes laboratory work time, ensuring the rapid generation of research results and enhancing overall research productivity.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eProduct Name\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eHuman DVL1(Segment polarity protein dishevelled homolog DVL-1) ELISA Kit\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAlias\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eDVL1 ELISA Kit\u003c\/span\u003e\u003c\/i\u003e\u003cspan style=\"font-weight: 400;\"\u003e, \u003c\/span\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eSegment polarity protein dishevelled homolog DVL-1 ELISA Kit\u003c\/span\u003e\u003c\/i\u003e\u003cspan style=\"font-weight: 400;\"\u003e, \u003c\/span\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eDishevelled-1 ELISA Kit\u003c\/span\u003e\u003c\/i\u003e\u003cspan style=\"font-weight: 400;\"\u003e, \u003c\/span\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eDSH homolog 1 ELISA Kit\u003c\/span\u003e\u003c\/i\u003e\u003cspan style=\"font-weight: 400;\"\u003e, \u003c\/span\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eDVL ELISA Kit\u003c\/span\u003e\u003c\/i\u003e\u003cspan style=\"font-weight: 400;\"\u003e, \u003c\/span\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003edishevelled ELISA Kit\u003c\/span\u003e\u003c\/i\u003e\u003cspan style=\"font-weight: 400;\"\u003e, \u003c\/span\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003edsh homolog 1 ELISA Kit\u003c\/span\u003e\u003c\/i\u003e\u003cspan style=\"font-weight: 400;\"\u003e, \u003c\/span\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eDrosophila ELISA Kit\u003c\/span\u003e\u003c\/i\u003e\u003cspan style=\"font-weight: 400;\"\u003e, \u003c\/span\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003edishevelled 1 ELISA Kit\u003c\/span\u003e\u003c\/i\u003e\u003cspan style=\"font-weight: 400;\"\u003e, \u003c\/span\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003ehomologous to Drosophila dsh ELISA Kit\u003c\/span\u003e\u003c\/i\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDetection Method\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSandwich ELISA, Double Antibody\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.fn-test.com\/?post_type=product\u0026amp;s=DVL1\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eDVL1 ELISA Kit\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"font-weight: 400;\"\u003e allows for the in vitro quantitative determination of DVL1 concentrations in serum, plasma, tissue homogenates and other biological fluids.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSize\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e96T\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e0.156-10ng\/ml\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSensitivity\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u0026lt; 0.094ng\/ml\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSpecies\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eHuman\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eUniProt ID\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/www.uniprot.org\/uniprot\/O14640\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eO14640\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eStandard Curve\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cimg src=\"https:\/\/www.fn-test.com\/content\/uploads\/product\/images\/elisa\/standard-curve\/EH1769.jpg\"\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eStorage\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e2-8 ℃ for 6 months\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eRecovery\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMatrices listed below were spiked with certain level of DVL1 and the recovery rates were calculated by comparing the measured value to the expected amount of DVL1 in samples.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eMatrix\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eRecovery range(%)\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eAverage(%)\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eserum(n=5)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e91-104\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e100\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eEDTA plasma(n=5)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e87-101\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e94\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eheparin plasma(n=5)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e86-103\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e94\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eLinearity\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe linearity of the kit was assayed by testing samples spiked with appropriate concentration of DVL1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eSample\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003e1:2\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003e1:4\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003e1:8\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eserum(n=5)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e97-105%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e88-104%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e91-98%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eEDTA plasma(n=5)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e84-98%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e86-100%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e87-101%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eheparin plasma(n=5)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e81-90%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e82-98%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e82-98%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eCV(%)\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eIntra-Assay: CV\u0026lt;8%\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eInter-Assay: CV\u0026lt;10%\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNote\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFor Research Use Only\u003c\/span\u003e\u003c\/p\u003e","brand":"FineTest","offers":[{"title":"96T \/ 0.094ng\/ml \/ 0.156-10ng\/ml","offer_id":42522772603104,"sku":"EH1769","price":450.0,"currency_code":"KRW","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/9330\/8896\/products\/EM2109_f1532d40-f251-40e9-8043-47f4883dd4d5.jpg?v=1690497896","url":"https:\/\/rndmate.com\/products\/human-dvl1-segment-polarity-protein-dishevelled-homolog-dvl-1-elisa-kit-eh1769","provider":"알앤디메이트","version":"1.0","type":"link"}