SKU(재고 관리 코드):ELK9759
Mouse ACA-IgG(Anti-Cardiolipin Antibody IgG) ELISA Kit
Mouse ACA-IgG(Anti-Cardiolipin Antibody IgG) ELISA Kit
Mouse ACA-IgG(Anti-Cardiolipin Antibody IgG) ELISA Kit
Overview
Product name: | Mouse ACA-IgG(Anti-Cardiolipin Antibody IgG) ELISA Kit |
Reactivity: | Mouse |
Alternative Names: | ACA-IgG; Anti-Cardiolipin Antibody IgG |
Assay Type: | Sandwich |
Sensitivity: | 1.032 ng/mL |
Standard: | 200 ng/mL |
Detection Range: | 3.13-200 ng/mL |
Sample Type: | Serum, plasma, tissue homogenates and other biological fluids |
Assay Length: | 3.5h |
Research Area: | Cardiovascular biology |
Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse ACA-IgG. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse ACA-IgG. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse ACA-IgG, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse ACA-IgG in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
Concentration (ng/mL) | OD | Corrected OD |
---|---|---|
200.00 | 2.079 | 1.993 |
100.00 | 1.587 | 1.501 |
50.00 | 1.228 | 1.142 |
25.00 | 0.871 | 0.785 |
12.50 | 0.593 | 0.507 |
6.25 | 0.321 | 0.235 |
3.13 | 0.213 | 0.127 |
0.00 | 0.086 | 0.000 |
Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant ACA-IgG and the recovery rates were calculated by comparing the measured value to the expected amount of ACA-IgG in samples.
Matrix | Recovery range | Average |
---|---|---|
serum(n=5) | 92-107% | 99% |
EDTA plasma(n=5) | 89-103% | 96% |
Heparin plasma(n=5) | 85-101% | 93% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ACA-IgG and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
---|---|---|---|---|
serum(n=5) | 87-98% | 85-96% | 80-96% | 84-98% |
EDTA plasma(n=5) | 91-97% | 81-93% | 90-99% | 81-97% |
Heparin plasma(n=5) | 85-96% | 91-101% | 87-98% | 95-104% |