제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMB450Ge

Magnetic Luminex Assay Kit for Carnosine (Car) ,etc.

Magnetic Luminex Assay Kit for Carnosine (Car) ,etc.

Detection range
Size
Sensitivity

Product No.

LMB450Ge

Organism Species

Pan-species (General).

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.

Test Method

Competitive Inhibition

Assay Length

1.5h

Detection Range

0.88-900ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.293 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Carnosine (Car) ,etc..
No significant cross-reactivity or interference between Carnosine (Car) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of Carnosine (Car) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Carnosine (Car) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 85-101 89
EDTA plasma(n=5) 80-92 87
heparin plasma(n=5) 84-93 88
sodium citrate plasma(n=5) 92-105 98

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Carnosine (Car) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Carnosine (Car) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Carnosine (Car) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-104% 95-104% 96-104% 79-93%
EDTA plasma(n=5) 79-89% 83-94% 96-105% 81-105%
heparin plasma(n=5) 82-95% 93-101% 98-105% 96-103%
sodium citrate plasma(n=5) 87-96% 93-101% 92-99% 98-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:Car) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine. 

     

    Magazine Citations
    Springerplus Dietary supplemental vitamin B6 increases carnosine and anserine concentrations in the heart of rats PubMed: 26101732
    Mol Nutr Food Res Zinc supplementation influences genomic stability biomarkers, antioxidant activity, and zinc transporter genes in an elderly Australian population with low zinc status PubMed: 25755079
    Pediatric Diabetes The effect of 12 weeks carnosine supplementation on renal functional integrity and oxidative stress in pediatric patients with diabetic nephropathy: a randomized placebo-controlled trial pubmed:28744992
    Arch. Anim. Breed The effect of genotype and muscle type on the physico-chemical characteristics and taurine, carnosine and L-carnitine concentration in lamb meat 33473367
    Catalog No. Related products for research use of Pan-species (General) Organism species Applications (RESEARCH USE ONLY!)
    CPB450Ge11 BSA Conjugated Carnosine (Car) Immunogen; SDS-PAGE; WB.
    CPB450Ge21 OVA Conjugated Carnosine (Car) Immunogen; SDS-PAGE; WB.
    PAB450Ge01 Polyclonal Antibody to Carnosine (Car) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
    CEB450Ge ELISA Kit for Carnosine (Car) Enzyme-linked immunosorbent assay for Antigen Detection.
    LMB450Ge Magnetic Luminex Assay Kit for Carnosine (Car) ,etc. Magnetic Luminex Assay for Antigen Detection.
    KSB450Ge11 ELISA Kit DIY Materials for Carnosine (Car) Main materials for "Do It (ELISA Kit) Yourself".
    전체 세부 정보 보기