Cloud-clone

SKU(재고 관리 코드):LMB354Hu

Magnetic Luminex Assay Kit for Aryl Hydrocarbon Receptor (AhR) ,etc.

Magnetic Luminex Assay Kit for Aryl Hydrocarbon Receptor (AhR) ,etc.

Detection range
Size
Sensitivity

Product No.

LMB354Hu

Organism Species

Homo sapiens (Human).

Sample Type

tissue homogenates, cell lysates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

4.88-5000pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 1.627 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Aryl Hydrocarbon Receptor (AhR) ,etc..
No significant cross-reactivity or interference between Aryl Hydrocarbon Receptor (AhR) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Aryl Hydrocarbon Receptor (AhR) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Aryl Hydrocarbon Receptor (AhR) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 92-105 95
EDTA plasma(n=5) 87-96 92
heparin plasma(n=5) 90-105 98
sodium citrate plasma(n=5) 98-105 102

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Aryl Hydrocarbon Receptor (AhR) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Aryl Hydrocarbon Receptor (AhR) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Aryl Hydrocarbon Receptor (AhR) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 97-105% 88-95% 78-90% 80-101%
EDTA plasma(n=5) 96-104% 79-102% 99-105% 86-105%
heparin plasma(n=5) 87-103% 97-105% 80-98% 83-93%
sodium citrate plasma(n=5) 79-101% 88-96% 83-98% 86-102%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:AhR) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Molecular and Cellular Endocrinology Isomer-nonspecific action of dichlorodiphenyltrichloroethane on aryl hydrocarbon receptor and G-protein-coupled receptor 30 intracellular signaling in apoptotic neuronal cells Pubmed:24859647
Journal of Steroid Biochemistry and Molecular Biology Depressive-like effect of prenatal exposure to DDT involves global DNA hypomethylation and impairment of GPER1/ESR1 protein levels but not ESR2 and AHR/ARNT signaling pubmed:28263910
Biol Trace Elem Res Investigation of Aryl Hydrocarbon Receptor, Zinc, and Vitamin B12 Levels in Chronic Gastritis with Helicobacter pylori Infection 33723799
Int J Clin Pract Association of aryl hydrocarbon receptor (AhR) serum level and gene rs10247158 polymorphism with anthropometric, biochemical parameters and food consumption ¡­ 34091989
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB354Hu01 Recombinant Aryl Hydrocarbon Receptor (AhR) Positive Control; Immunogen; SDS-PAGE; WB.
PAB354Hu01 Polyclonal Antibody to Aryl Hydrocarbon Receptor (AhR) WB,IHC
MAB354Hu22 Monoclonal Antibody to Aryl Hydrocarbon Receptor (AhR) WB; IHC; ICC; IP.
MAB354Hu21 Monoclonal Antibody to Aryl Hydrocarbon Receptor (AhR) WB; IHC; ICC; IP.
SEB354Hu ELISA Kit for Aryl Hydrocarbon Receptor (AhR) Enzyme-linked immunosorbent assay for Antigen Detection.
SCB354Hu CLIA Kit for Aryl Hydrocarbon Receptor (AhR) Chemiluminescent immunoassay for Antigen Detection.
LMB354Hu Magnetic Luminex Assay Kit for Aryl Hydrocarbon Receptor (AhR) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기