제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMG200Hu

Magnetic Luminex Assay Kit for Epithelial Stromal Interaction 1, Breast (EPSTI1) ,etc.

Magnetic Luminex Assay Kit for Epithelial Stromal Interaction 1, Breast (EPSTI1) ,etc.

Detection range
Size
Sensitivity

Product No.

LMG200Hu

Organism Species

Homo sapiens (Human).

Sample Type

Tissue homogenates and other biological fluids.

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.02-20ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.007 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Epithelial Stromal Interaction 1, Breast (EPSTI1) ,etc..
No significant cross-reactivity or interference between Epithelial Stromal Interaction 1, Breast (EPSTI1) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Epithelial Stromal Interaction 1, Breast (EPSTI1) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Epithelial Stromal Interaction 1, Breast (EPSTI1) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 95-103 101
EDTA plasma(n=5) 79-93 84
heparin plasma(n=5) 83-90 86

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Epithelial Stromal Interaction 1, Breast (EPSTI1) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Epithelial Stromal Interaction 1, Breast (EPSTI1) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Epithelial Stromal Interaction 1, Breast (EPSTI1) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-95% 96-103% 87-96% 78-95%
EDTA plasma(n=5) 92-105% 96-104% 86-102% 82-99%
heparin plasma(n=5) 84-98% 87-103% 80-91% 95-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:EPSTI1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPG200Hu01 Recombinant Epithelial Stromal Interaction 1, Breast (EPSTI1) Positive Control; Immunogen; SDS-PAGE; WB.
PAG200Hu01 Polyclonal Antibody to Epithelial Stromal Interaction 1, Breast (EPSTI1) WB; IHC; ICC; IP.
MAG200Hu21 Monoclonal Antibody to Epithelial Stromal Interaction 1, Breast (EPSTI1) WB; IHC; ICC; IP.
SEG200Hu ELISA Kit for Epithelial Stromal Interaction 1, Breast (EPSTI1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMG200Hu Magnetic Luminex Assay Kit for Epithelial Stromal Interaction 1, Breast (EPSTI1) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기