SKU(재고 관리 코드):LML231Hu
Magnetic Luminex Assay Kit for Alpha-2-Glycoprotein 1, Zinc Binding (aZGP1) ,etc.
Magnetic Luminex Assay Kit for Alpha-2-Glycoprotein 1, Zinc Binding (aZGP1) ,etc.
Product No.
LML231Hu
Organism Species
Homo sapiens (Human).
Sample Type
Serum, plasma, urine, saliva, seminal plasma, sweat and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.29-300ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.097 ng/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Alpha-2-Glycoprotein 1, Zinc Binding (aZGP1) ,etc..
No significant cross-reactivity or interference between Alpha-2-Glycoprotein 1, Zinc Binding (aZGP1) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Alpha-2-Glycoprotein 1, Zinc Binding (aZGP1) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Alpha-2-Glycoprotein 1, Zinc Binding (aZGP1) ,etc. in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 89-102 | 96 |
EDTA plasma(n=5) | 82-94 | 87 |
heparin plasma(n=5) | 89-96 | 93 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Alpha-2-Glycoprotein 1, Zinc Binding (aZGP1) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Alpha-2-Glycoprotein 1, Zinc Binding (aZGP1) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Alpha-2-Glycoprotein 1, Zinc Binding (aZGP1) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 89-96% | 98-105% | 89-103% | 88-96% |
EDTA plasma(n=5) | 80-97% | 89-97% | 82-94% | 96-103% |
heparin plasma(n=5) | 94-101% | 96-103% | 84-101% | 78-99% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:aZGP1) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
Magazine | Citations |
Journal of Proteomics | Identification of plasma Complement C3 as a potential biomarker for neuroblastoma using a quantitative proteomic approach ScienceDirect: S1874391913005472 |
International journal of endocrinology | Serum ZAG Levels Were Associated with eGFR Mild Decrease in T2DM Patients with Diabetic Nephropathy. pubmed:28352283 |
Quantitative Proteomic Analyses of Tear Fluid in Graves' Orbitopathy ISBN 978-82-8377-114-5 | |
Frontiers in Endocrinology | Circulating and Adipose Tissue mRNA Levels of Zinc-α2-Glycoprotein, Leptin, High-Molecular-Weight Adiponectin, and Tumor Necrosis Factor-Alpha in … Pubmed:29755407 |
International Journal of Endocrinology | Serum Zinc-α2-Glycoprotein Levels in Patients with or without Coronary Artery Disease in Chinese North Population Pubmed: 32184822 |
Frontiers in Endocrinology | Low Serum ZAG Levels Correlate With Determinants of the Metabolic Syndrome in Chinese Subjects Pubmed: 32265843 |
Diabetes Metab Syndr Obes | Serum ZAG and Adiponectin Levels Were Closely Related to Obesity and the Metabolically Abnormal Phenotype in Chinese Population Pubmed: 32904655 |
J Endocrinol Invest | A study on serum pro-neurotensin (PNT), furin, and zinc alpha-2-glycoprotein (ZAG) levels in patients with acromegaly Pubmed:35670958 |