Cloud-clone

SKU(재고 관리 코드):LML638Ra

Magnetic Luminex Assay Kit for JNK1/MAPK8 Associated Membrane Protein (JKAMP) ,etc.

Magnetic Luminex Assay Kit for JNK1/MAPK8 Associated Membrane Protein (JKAMP) ,etc.

Detection range
Size
Sensitivity

Product No.

LML638Ra

Organism Species

Rattus norvegicus (Rat).

Sample Type

tissue homogenates, cell lysates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.1-100ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.033 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of JNK1/MAPK8 Associated Membrane Protein (JKAMP) ,etc..
No significant cross-reactivity or interference between JNK1/MAPK8 Associated Membrane Protein (JKAMP) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant JNK1/MAPK8 Associated Membrane Protein (JKAMP) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of JNK1/MAPK8 Associated Membrane Protein (JKAMP) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 97-104 101
EDTA plasma(n=5) 79-97 84
heparin plasma(n=5) 93-101 96
sodium citrate plasma(n=5) 93-104 99

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level JNK1/MAPK8 Associated Membrane Protein (JKAMP) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level JNK1/MAPK8 Associated Membrane Protein (JKAMP) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of JNK1/MAPK8 Associated Membrane Protein (JKAMP) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 96-104% 83-98% 81-103% 84-92%
EDTA plasma(n=5) 87-98% 97-105% 81-97% 83-95%
heparin plasma(n=5) 82-89% 87-103% 94-102% 85-101%
sodium citrate plasma(n=5) 81-94% 89-101% 81-97% 94-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:JKAMP) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Environ Toxicol Pharmacol. Targetingp53/TRAIL/caspase-8 signaling by adiponectin reverses thioacetamide-induced hepatocellular carcinoma in rats Pubmed: 31421311
Int Immunopharmacol Cardio-protective impact of gabapentin against doxorubicin-induced myocardial toxicity in rats; emphasis on modulation of inflammatory-apoptotic signaling Pubmed: 33199237
ENVIRONMENTAL TOXICOLOGY AND PHARMACOLOGY Chemo-preventive effect of crocin against experimentally-induced hepatocarcinogenesis via regulation of apoptotic and Nrf2 signaling pathways Pubmed: 32942000
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPL638Ra01 Recombinant JNK1/MAPK8 Associated Membrane Protein (JKAMP) Positive Control; Immunogen; SDS-PAGE; WB.
PAL638Ra01 Polyclonal Antibody to JNK1/MAPK8 Associated Membrane Protein (JKAMP) WB; IHC; ICC; IP.
MAL638Ra21 Monoclonal Antibody to JNK1/MAPK8 Associated Membrane Protein (JKAMP) WB; IHC; ICC; IP.
SEL638Ra ELISA Kit for JNK1/MAPK8 Associated Membrane Protein (JKAMP) Enzyme-linked immunosorbent assay for Antigen Detection.
LML638Ra Magnetic Luminex Assay Kit for JNK1/MAPK8 Associated Membrane Protein (JKAMP) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기