제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMA568Mu

Magnetic Luminex Assay Kit for S100 Calcium Binding Protein A11 (S100A11) ,etc.

Magnetic Luminex Assay Kit for S100 Calcium Binding Protein A11 (S100A11) ,etc.

Detection range
Size
Sensitivity

Product No.

LMA568Mu

Organism Species

Mus musculus (Mouse).

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.39-400pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.13 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of S100 Calcium Binding Protein A11 (S100A11) ,etc..
No significant cross-reactivity or interference between S100 Calcium Binding Protein A11 (S100A11) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant S100 Calcium Binding Protein A11 (S100A11) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of S100 Calcium Binding Protein A11 (S100A11) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 79-92 88
EDTA plasma(n=5) 94-101 97
heparin plasma(n=5) 82-89 86
sodium citrate plasma(n=5) 93-104 98

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level S100 Calcium Binding Protein A11 (S100A11) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level S100 Calcium Binding Protein A11 (S100A11) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of S100 Calcium Binding Protein A11 (S100A11) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 97-105% 97-105% 79-91% 80-101%
EDTA plasma(n=5) 89-96% 90-98% 79-98% 89-97%
heparin plasma(n=5) 81-91% 93-102% 90-104% 82-94%
sodium citrate plasma(n=5) 78-92% 98-105% 92-105% 79-94%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:S100A11) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Gastroenterology Tu1938-Micronutrients Assessment in Patients with Cirrhosis 10.1016:S0016-5085(18)33544-3
Gastroenterology Tu1942-PI3K/AKT-Mediated Upregulation of C7 Inhibits Colorectal Cancer Proliferation and Metastasis 10.1016:S0016-5085(18)33544-5
Journal of Proteomics Salivary proteins from dysplastic leukoplakia and oral squamous cell carcinoma and their potential for early detection Pubmed: 31706945
scandinavian journal of clinical & laboratory investigation Serum S100A6, S100A8, S100A9 and S100A11 proteins in colorectal neoplasia: results of a single centre prospective study Pubmed: 31856598
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPA568Mu02 Recombinant S100 Calcium Binding Protein A11 (S100A11) Positive Control; Immunogen; SDS-PAGE; WB.
RPA568Mu01 Recombinant S100 Calcium Binding Protein A11 (S100A11) Positive Control; Immunogen; SDS-PAGE; WB.
PAA568Mu02 Polyclonal Antibody to S100 Calcium Binding Protein A11 (S100A11) WB; IHC; ICC; IP.
PAA568Mu01 Polyclonal Antibody to S100 Calcium Binding Protein A11 (S100A11) WB; IHC; ICC; IP.
SEA568Mu ELISA Kit for S100 Calcium Binding Protein A11 (S100A11) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA568Mu Magnetic Luminex Assay Kit for S100 Calcium Binding Protein A11 (S100A11) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기