제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMA259Hu

Magnetic Luminex Assay Kit for Annexin V (ANXA5) ,etc.

Magnetic Luminex Assay Kit for Annexin V (ANXA5) ,etc.

Detection range
Size
Sensitivity

Product No.

LMA259Hu

Organism Species

Homo sapiens (Human) Same name, Different species.

Sample Type

Serum, plasma, tissue homogenates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

1.95-2000pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.65 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

Specificity

This assay has high sensitivity and excellent specificity for detection of Annexin V (ANXA5) ,etc..
No significant cross-reactivity or interference between Annexin V (ANXA5) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Annexin V (ANXA5) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Annexin V (ANXA5) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 98-105 101
EDTA plasma(n=5) 96-105 101
heparin plasma(n=5) 82-101 86
sodium citrate plasma(n=5) 98-105 102

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Annexin V (ANXA5) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Annexin V (ANXA5) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Annexin V (ANXA5) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 94-105% 78-91% 82-105% 87-94%
EDTA plasma(n=5) 81-102% 79-101% 97-105% 96-104%
heparin plasma(n=5) 88-98% 92-105% 79-95% 87-94%
sodium citrate plasma(n=5) 80-97% 80-98% 84-101% 85-92%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:ANXA5) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Molecular Biology Markers of apoptotic dysfunctions in schizophrenia Pubmed: 24466757
Neuroscience and Behavioral Physiology Involvement of Anomalous Apoptosis in Impairments to Synaptic Plasticity in Post-Traumatic Stress Disorder Springer: Source
Inflammation and Cell Signaling Collectins, C3 complement protein, annexin V and C-reactive protein in acute ischemic stroke: interrelation and implication to upregulated apoptosis and inflammation Smartscitech: Source
Lung Annexin A5 Protein as a Potential Biomarker for the Diagnosis of Asthma Pubmed: 30182154
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA259Hu04 Recombinant Annexin V (ANXA5) Positive Control; Immunogen; SDS-PAGE; WB.
RPA259Hu01 Recombinant Annexin V (ANXA5) Positive Control; Immunogen; SDS-PAGE; WB.
RPA259Hu05 Recombinant Annexin V (ANXA5) Positive Control; Immunogen; SDS-PAGE; WB.
EPA259Hu61 Eukaryotic Annexin V (ANXA5) Positive Control; Immunogen; SDS-PAGE; WB.
APA259Hu61 Active Annexin V (ANXA5) Cell culture; Activity Assays.
RPA259Hu06 Recombinant Annexin V (ANXA5) Positive Control; Immunogen; SDS-PAGE; WB.
RPA259Hu03 Recombinant Annexin V (ANXA5) Positive Control; Immunogen; SDS-PAGE; WB.
RPA259Hu02 Recombinant Annexin V (ANXA5) Positive Control; Immunogen; SDS-PAGE; WB.
PAA259Hu01 Polyclonal Antibody to Annexin V (ANXA5) WB; IHC; ICC; IP.
LAA259Hu71 Biotin-Linked Polyclonal Antibody to Annexin V (ANXA5) WB; IHC; ICC.
LAA259Hu81 FITC-Linked Polyclonal Antibody to Annexin V (ANXA5) WB; IHC; ICC; IF.
MAA259Hu21 Monoclonal Antibody to Annexin V (ANXA5) WB; IHC; ICC; IP.
MAA259Hu22 Monoclonal Antibody to Annexin V (ANXA5) WB,IHC
FAA259Hu02 Anti-Annexin V (ANXA5) Monoclonal Antibody FCM
LAA259Hu82 FITC-Linked Monoclonal Antibody to Annexin V (ANXA5) WB; IHC; ICC; IF.
LAA259Hu72 Biotin-Linked Monoclonal Antibody to Annexin V (ANXA5) WB; IHC; ICC.
FAA259Hu82 FITC-Linked Anti-Annexin V (ANXA5) Monoclonal Antibody FCM
SEA259Hu ELISA Kit for Annexin V (ANXA5) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA259Hu Magnetic Luminex Assay Kit for Annexin V (ANXA5) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기