Magnetic Luminex Assay Kit for Orosomucoid 2 (ORM2) ,etc.
Magnetic Luminex Assay Kit for Orosomucoid 2 (ORM2) ,etc.
Product No.
LMB780Hu
Organism Species
Homo sapiens (Human).
Sample Type
serum, plasma and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.05-50ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.017 ng/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Orosomucoid 2 (ORM2) ,etc..
No significant cross-reactivity or interference between Orosomucoid 2 (ORM2) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Orosomucoid 2 (ORM2) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Orosomucoid 2 (ORM2) ,etc. in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 95-102 | 99 |
EDTA plasma(n=5) | 97-105 | 101 |
heparin plasma(n=5) | 81-98 | 95 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Orosomucoid 2 (ORM2) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Orosomucoid 2 (ORM2) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Orosomucoid 2 (ORM2) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 79-89% | 88-95% | 99-105% | 93-101% |
EDTA plasma(n=5) | 84-98% | 96-103% | 79-95% | 81-101% |
heparin plasma(n=5) | 79-96% | 94-105% | 99-105% | 90-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:ORM2) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
Magazine | Citations |
Clin Exp Nephrol | Differentially expressed urinary biomarkers in children with idiopathic nephrotic syndrome PubMed: 26351173 |
Free Patents online | RHEUMATOID ARTHRITIS RELATED BIOMARKER 20170350884 |
Osteoarthritis and Cartilage | Orosomucoid 2 serves for predicting but not for monitoring drug response in patients with knee osteoarthritis treated with chondroitin sulfate/glucosamine … 10.1016:j.joca.2018.02.412 |
Therapeutic Advances in Chronic Disease | Predictive modeling of therapeutic response to chondroitin sulfate/glucosamine hydrochloride in knee osteoarthritis |
Journal of Cosmetic Dermatology | Evaluation of serum and urinary orsomucoid protein A in psoriatic patients and their relation to severity of disease 33905172 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
RPB780Hu01 | Recombinant Orosomucoid 2 (ORM2) | Positive Control; Immunogen; SDS-PAGE; WB. |
CPB780Hu21 | OVA Conjugated Orosomucoid 2 (ORM2) | Immunogen; SDS-PAGE; WB. |
PAB780Hu01 | Polyclonal Antibody to Orosomucoid 2 (ORM2) | WB; IHC; ICC; IP. |
LAB780Hu81 | FITC-Linked Polyclonal Antibody to Orosomucoid 2 (ORM2) | WB; IHC; ICC; IF. |
LAB780Hu71 | Biotin-Linked Polyclonal Antibody to Orosomucoid 2 (ORM2) | WB; IHC; ICC. |
MAB780Hu22 | Monoclonal Antibody to Orosomucoid 2 (ORM2) | WB,IHC |
MAB780Hu21 | Monoclonal Antibody to Orosomucoid 2 (ORM2) | WB; IHC; ICC; IP. |
SEB780Hu | ELISA Kit for Orosomucoid 2 (ORM2) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB780Hu | Magnetic Luminex Assay Kit for Orosomucoid 2 (ORM2) ,etc. | Magnetic Luminex Assay for Antigen Detection. |