제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMA045Ra

Magnetic Luminex Assay Kit for Colony Stimulating Factor 2, Granulocyte Macrophage (GM-CSF) ,etc.

Magnetic Luminex Assay Kit for Colony Stimulating Factor 2, Granulocyte Macrophage (GM-CSF) ,etc.

Detection range
Size
Sensitivity

Product No.

LMA045Ra

Organism Species

Rattus norvegicus (Rat).

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.49-500pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.163 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

    Specificity

    This assay has high sensitivity and excellent specificity for detection of Colony Stimulating Factor 2, Granulocyte Macrophage (GM-CSF) ,etc..
    No significant cross-reactivity or interference between Colony Stimulating Factor 2, Granulocyte Macrophage (GM-CSF) ,etc. and analogues was observed.

    Recovery

    Matrices listed below were spiked with certain level of recombinant Colony Stimulating Factor 2, Granulocyte Macrophage (GM-CSF) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Colony Stimulating Factor 2, Granulocyte Macrophage (GM-CSF) ,etc. in samples.

    Matrix Recovery range (%) Average(%)
    serum(n=5) 84-102 90
    EDTA plasma(n=5) 80-102 83
    heparin plasma(n=5) 83-101 93

    Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Colony Stimulating Factor 2, Granulocyte Macrophage (GM-CSF) ,etc. were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Colony Stimulating Factor 2, Granulocyte Macrophage (GM-CSF) ,etc. were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Linearity

    The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Colony Stimulating Factor 2, Granulocyte Macrophage (GM-CSF) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

    Sample 1:2 1:4 1:8 1:16
    serum(n=5) 92-101% 82-103% 82-97% 89-98%
    EDTA plasma(n=5) 78-89% 96-103% 88-96% 79-91%
    heparin plasma(n=5) 81-102% 79-101% 97-105% 96-104%

    Stability

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Reagents and materials provided

    Reagents Quantity Reagents Quantity
    96-well plate 1 Plate sealer for 96 wells 4
    Pre-Mixed Standard 2 Standard Diluent 1×20mL
    Pre-Mixed Magnetic beads (22#:GM-CSF) 1 Analysis buffer 1×20mL
    Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
    Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
    Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
    Instruction manual 1

    Assay procedure summary

    1. Preparation of standards, reagents and samples before the experiment;
    2. Add 100μL standard or sample to each well,
        add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
    3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
    4. Wash plate on magnetic frame for three times;
    5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
    6. Wash plate on magnetic frame for three times;
    7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

    Magazine Citations
    Journal of Toxicology and Environmental Health Effects of 900-MHz Microwave Radiation on γ-Ray-Induced Damage to Mouse Hematopoietic System PubMed: 20391130
    5 Safety and efficacy of the peptide-based therapeutic vaccine for HIV-1, Vacc-4×: a phase 2 randomised, double-blind, placebo-controlled trial Pubmed:24525316
    Archives of Virology Genetic and immunogenicity analysis of porcine circovirus type 2 strains isolated in central China Pubmed:29305646
    BioMed Research International Activated Macrophages of Monocytic Origin Predominantly Express Proinflammatory Cytokine Genes, Whereas Kupffer Cells Predominantly Express Anti …
    bulletin of experimental biology and medicine Quantitative and Qualitative Characterization of Phagocytic Activity of Macrophages of Bone Marrow and Fetal Origin Pubmed: 31183654
    Exp Mol Pathol The regulatory role of SFRP5/WNT5A axis in allergic rhinitis through inhibiting JNK pathway activation and lowering mucin generation in human nasal?¡­ 33285209
    Vaccine Co-delivery of PSMA antigen epitope and mGM-CSF with a cholera toxin-like chimeric protein suppressed prostate tumor growth via activating dendritic cells and?¡­ 33612342
    Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
    APA045Ra01 Active Colony Stimulating Factor 2, Granulocyte Macrophage (GM-CSF) Cell culture; Activity Assays.
    RPA045Ra01 Recombinant Colony Stimulating Factor 2, Granulocyte Macrophage (GM-CSF) Positive Control; Immunogen; SDS-PAGE; WB.
    PAA045Ra01 Polyclonal Antibody to Colony Stimulating Factor 2, Granulocyte Macrophage (GM-CSF) WB; IHC; ICC; IP.
    MAA045Ra21 Monoclonal Antibody to Colony Stimulating Factor 2, Granulocyte Macrophage (GM-CSF) WB; IHC; ICC; IP.
    SEA045Ra ELISA Kit for Colony Stimulating Factor 2, Granulocyte Macrophage (GM-CSF) Enzyme-linked immunosorbent assay for Antigen Detection.
    SCA045Ra CLIA Kit for Colony Stimulating Factor 2, Granulocyte Macrophage (GM-CSF) Chemiluminescent immunoassay for Antigen Detection.
    LMA045Ra Magnetic Luminex Assay Kit for Colony Stimulating Factor 2, Granulocyte Macrophage (GM-CSF) ,etc. Magnetic Luminex Assay for Antigen Detection.
    전체 세부 정보 보기