SKU(재고 관리 코드):CEA170Ra
ELISA Kit for Activin B (ACVB)
ELISA Kit for Activin B (ACVB)
Enzyme-linked immunosorbent assay for Antigen Detection.
Product No.
CEA170Ra
Organism Species
Rattus norvegicus (Rat).
Sample Type
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Test Method
Competitive Inhibition
Assay Length
2h
Detection Range
12.35-1,000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 5.29pg/mL.
UOM
48T 96T 96T*5 96T*10 96T*100
Specificity
This assay has high sensitivity and excellent specificity for detection of Activin B (ACVB).
No significant cross-reactivity or interference between Activin B (ACVB) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Activin B (ACVB) and the recovery rates were calculated by comparing the measured value to the expected amount of Activin B (ACVB) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 95-102 | 99 |
EDTA plasma(n=5) | 98-105 | 102 |
heparin plasma(n=5) | 80-99 | 86 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Activin B (ACVB) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Activin B (ACVB) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Activin B (ACVB) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 80-90% | 85-104% | 98-105% | 91-99% |
EDTA plasma(n=5) | 90-97% | 78-93% | 93-104% | 87-101% |
heparin plasma(n=5) | 90-104% | 90-98% | 78-101% | 89-102% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1 | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
Reagent Diluent | 1×300µL | Stop Solution | 1×6mL |
TMB Substrate | 1×9mL | Instruction manual | 1 |
Wash Buffer (30 × concentrate) | 1×20mL |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.
Magazine | Citations |
Gastroenterology Research and Practice | Serum Activins and Follistatin during the Treatment of Chronic Hepatitis C Genotypes 1 and 4 and Their Correlations with Viral Load and Liver Enzymes: A Preliminary Report. Pubmed: 24799891 |
Gastroenterol Res Pract.? | Serum activins and follistatin during the treatment of chronic hepatitis c genotypes 1 and 4 and their correlations with viral load and liver enzymes: A preliminary report Pubmed:Pmc3995172 |
Clin Exp Med.? | Effects?of?chronic hepatitis C?genotype?1?and 4 on serum activins and follistatin in treatment na?ve patients and their correlations with interleukin-6, tumour necrosis factor-α, viral load and liver damage. Pubmed:24925642 |
Clin Biochem | Serum activin B concentration as predictive biomarker for ectopic pregnancy Pubmed:26968108 |
BMC Cancer. | Activins and their related proteins in colon carcinogenesis: insights from early and advanced azoxymethane rat models of colon cancer. pubmed:27835986 |
Australasian Journal of Ultrasound in Medicine | The potential value of activin B and fibronectin for the triage of pregnancies of unknown location and prediction of first trimester viability 10.1002:ajum.12090 |
Pathology & Oncology Research | Profiling Activins and Follistatin in Colorectal Cancer According to Clinical Stage, Tumour Sidedness and Smad4 Status 34867090 |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
CEA170Ra | ELISA Kit for Activin B (ACVB) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA170Ra | Magnetic Luminex Assay Kit for Activin B (ACVB) ,etc. | Magnetic Luminex Assay for Antigen Detection. |