SKU(재고 관리 코드):ELK9511
Goat HSP-70/HSPA9(HeatShock Protein 70) ELISA Kit
Goat HSP-70/HSPA9(HeatShock Protein 70) ELISA Kit
Goat HSP-70/HSPA9(HeatShock Protein 70) ELISA Kit
Overview
Product name: | Goat HSP-70/HSPA9(HeatShock Protein 70) ELISA Kit |
Reactivity: | Goat |
Alternative Names: | DnaK; 70 Kilodalton Heat Shock Proteins;Heat shock 70 kDa protein 1; 2; heat shock 70kDa protein 1A; HSP70; HSP70 1; HSP70 1; HSP70 2; HSP70 1A; HSP70.1; HSP70.2; HSP70I; HSP72; HSPA1; HSPA1A; HSPA1B; HSP70; Heat Shock Protein 70 |
Assay Type: | Sandwich |
Sensitivity: | 1.29 ng/mL |
Standard: | 200 ng/mL |
Detection Range: | 3.13-200 ng/mL |
Sample Type: | serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids |
Assay Length: | 3.5h |
Research Area: | Tumor immunity;Infection immunity;Developmental science; |
Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Goat HSP-70/HSPA9. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Goat HSP-70/HSPA9. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Goat HSP-70/HSPA9, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Goat HSP-70/HSPA9 in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
Concentration (ng/mL) | OD | Corrected OD |
---|---|---|
200.00 | 2.268 | 2.174 |
100.00 | 1.727 | 1.633 |
50.00 | 1.188 | 1.094 |
25.00 | 0.852 | 0.758 |
12.50 | 0.492 | 0.398 |
6.25 | 0.355 | 0.261 |
3.13 | 0.236 | 0.142 |
0.00 | 0.094 | 0.000 |
Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant HSP-70/HSPA9 and the recovery rates were calculated by comparing the measured value to the expected amount of HSP-70/HSPA9 in samples.
Matrix | Recovery range | Average |
---|---|---|
serum(n=5) | 89-103% | 96% |
EDTA plasma(n=5) | 85-101% | 93% |
Heparin plasma(n=5) | 85-99% | 92% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HSP-70/HSPA9 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
---|---|---|---|---|
serum(n=5) | 85-96% | 93-104% | 93-104% | 89-97% |
EDTA plasma(n=5) | 85-94% | 87-103% | 89-98% | 80-101% |
Heparin plasma(n=5) | 87-96% | 92-104% | 82-96% | 95-102% |