Horse Lingo1(Leucine rich repeat and Ig domain containing 1) ELISA Kit

Horse Lingo1(Leucine rich repeat and Ig domain containing 1) ELISA Kit

Sensitivity

Horse Lingo1(Leucine rich repeat and Ig domain containing 1) ELISA Kit

Overview

Product name: Horse Lingo1(Leucine rich repeat and Ig domain containing 1) ELISA Kit
Reactivity: Horse
Alternative Names: FLJ14594; LERN 1; LERN1; Leucine rich repeat and Ig domain containing 1; Leucine rich repeat neuronal 6A; Leucine rich repeat neuronal protein 1; Leucine rich repeat neuronal protein 6A; Leucine-rich repeat and immunoglobilin domain-containing protein 1; Leucine-rich repeat and immunoglobulin-like domain-containing nogo receptor-interacting protein 1; Leucine-rich repeat neuronal protein 1; Leucine-rich repeat neuronal protein 6A; LIGO1_Horse; Lingo 1; LINGO1; LRR and Ig domain containing Nogo Receptor inteHorseing protein; Lrrn 6a; Lrrn6a; Lrrn6a protein; MGC17422; Nogo Receptor interacting protein; PRO227; UNQ201;
Assay Type: Sandwich
Sensitivity: 0.094 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Tissue homogenates, cell lysates and other biological fluids.
Assay Length: 3.5h
Research Area: Cardiovascular
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Horse Lingo1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Horse Lingo1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Horse Lingo1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Horse Lingo1 in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (ng/mL) OD Corrected OD
10.00 2.079 1.984
5.00 1.612 1.517
2.50 1.188 1.093
1.25 0.813 0.718
0.63 0.475 0.380
0.32 0.369 0.274
0.16 0.226 0.131
0.00 0.095 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant Lingo1 and the recovery rates were calculated by comparing the measured value to the expected amount of Lingo1 in samples.
Matrix Recovery range Average
serum(n=5) 83-99% 95%
EDTA plasma(n=5) 82-95% 88%
Heparin plasma(n=5) 80-95% 87%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Lingo1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 89-105% 90-101% 87-96% 92-105%
EDTA plasma(n=5) 79-96% 92-105% 91-99% 85-102%
Heparin plasma(n=5) 79-92% 85-97% 87-96% 82-95%