제품 정보로 건너뛰기
1 1

ELK Biotechnology

SKU(재고 관리 코드):ELK9673

Horse Presepsin(Presepsin) ELISA Kit

Horse Presepsin(Presepsin) ELISA Kit

Sensitivity

Horse Presepsin(Presepsin) ELISA Kit

Overview

Product name: Horse Presepsin(Presepsin) ELISA Kit
Reactivity: Horse
Alternative Names: soluble CD14 subtype; sCD14-ST; Presepsin
Assay Type: Sandwich
Sensitivity: 0.058 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Serum, plasma and other biological fluids
Assay Length: 3.5h
Research Area: Sepsis
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Horse Presepsin. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Horse Presepsin. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Horse Presepsin, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Horse Presepsin in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (ng/mL) OD Corrected OD
10.00 1.996 1.911
5.00 1.675 1.590
2.50 1.228 1.143
1.25 0.796 0.711
0.63 0.595 0.510
0.32 0.331 0.246
0.16 0.258 0.173
0.00 0.085 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant Presepsin and the recovery rates were calculated by comparing the measured value to the expected amount of Presepsin in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 81-97% 89%
Heparin plasma(n=5) 79-97% 88%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Presepsin and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-99% 79-93% 89-97% 89-97%
EDTA plasma(n=5) 85-101% 84-98% 88-97% 86-92%
Heparin plasma(n=5) 81-93% 89-105% 85-94% 79-96%