Overview
Product name: | Human A-GHRL(AcylatedGhrelin) ELISA Kit |
Reactivity: | Human |
Alternative Names: | A-GHRL |
Assay Type: | Sandwich |
Sensitivity: | 9.38 pg/mL |
Standard: | 1000 pg/mL |
Detection Range: | 15.63-1000 pg/mL |
Sample Type: | serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids |
Assay Length: | 3.5h |
Research Area: | Cardiovascular;Signal Transduction;Cardiovascular;Metabolism; |
Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human A-GHRL. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human A-GHRL. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human A-GHRL, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human A-GHRL in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
Concentration (ng/mL) | OD | Corrected OD |
---|---|---|
1000.00 | 1.946 | 1.861 |
500.00 | 1.572 | 1.487 |
250.00 | 1.282 | 1.197 |
125.00 | 0.952 | 0.867 |
62.50 | 0.518 | 0.433 |
31.25 | 0.357 | 0.272 |
15.63 | 0.194 | 0.109 |
0.00 | 0.085 | 0.000 |
Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant A-GHRL and the recovery rates were calculated by comparing the measured value to the expected amount of A-GHRL in samples.
Matrix | Recovery range | Average |
---|---|---|
serum(n=5) | 84-96% | 90% |
EDTA plasma(n=5) | 87-95% | 91% |
Heparin plasma(n=5) | 95-107% | 101% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of A-GHRL and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
---|---|---|---|---|
serum(n=5) | 85-97% | 95-107% | 92-103% | 81-99% |
EDTA plasma(n=5) | 80-96% | 93-105% | 83-97% | 95-104% |
Heparin plasma(n=5) | 82-93% | 81-96% | 79-91% | 83-94% |