Elabscience
SKU(재고 관리 코드):E-EL-H6020
Human C-P(C-Peptide) ELISA Kit
Human C-P(C-Peptide) ELISA Kit
가격·납기 및 기술자료를 확인해 드립니다.
제품 규격과 수량을 선택한 후 견적을 요청해 주세요. 대체품 검토와 SDS·COA·데이터시트 요청도 함께 접수할 수 있습니다.
이 제품 견적 요청대표번호 070-8028-3500 · info@rndmate.com
Properties
| Assay type | Sandwich-ELISA |
| Format | 96T/48T |
| Assay time | 3.5h |
| Detection range | 7.81-500 pg/mL |
| Sensitivity | 4.69 pg/mL |
| Sample type &Sample volume | serum, plasma and other biological fluids; 100μL |
| Specificity | This kit recognizes Human C-P in samples. No significant cross-reactivity or interference between Human C-P and analogues was observed. |
| Reproducibility | Both intra-CV and inter-CV are < 10%. |
| Application | This ELISA kit applies to the in vitro quantitative determination of Human C-P concentrations in serum, plasma and other biological fluids. |
Test Principle
Kit components & Storage
| Item | Specifications | Storage |
|---|---|---|
| Micro ELISA Plate(Dismountable) | 96T: 8 wells ×12 strips 48T: 8 wells ×6 strips |
-20℃, 6 months |
| Reference Standard | 96T: 2 vials 48T: 1 vial |
|
| Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 48T: 1 vial, 60 μL |
|
| Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 48T: 1 vial, 60 μL |
-20℃(Protect from light), 6 months |
| Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
| Biotinylated Detection Ab Diluent | 1 vial, 14 mL | |
| HRP Conjugate Diluent | 1 vial, 14 mL | |
| Concentrated Wash Buffer (25×) | 1 vial, 30 mL | |
| Substrate Reagent | 1 vial, 10 mL | 2-8℃(Protect from light) |
| Stop Solution | 1 vial, 10 mL | 2-8°C |
| Plate Sealer | 5 pieces | |
| Manual | 1 copy | |
| Certificate of Analysis | 1 copy |
Technical Data
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Human C-P were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Human C-P were tested on 3 different plates, 20 replicates in each plate.
| Intra-assay Precision | Inter-assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 20 | 20 | 20 | 20 | 20 | 20 |
| Mean (pg/mL) | 24.00 | 56.70 | 249.89 | 22.74 | 53.34 | 200.91 |
| Standard deviation | 1.33 | 2.65 | 11.00 | 1.27 | 2.41 | 10.75 |
| CV (%) | 5.54 | 4.67 | 4.40 | 5.58 | 4.52 | 5.35 |
Recovery
The recovery of Human C-P spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
| Sample Type | Range (%) | Average Recovery (%) |
|---|---|---|
| Serum(n=8) | 102-113 | 105 |
| EDTA plasma (n=8) | 87-96 | 92 |
| Cell culture media (n=8) | 97-109 | 101 |
Linearity
Samples were spiked with high concentrations of Human C-P and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.

Target Information
| Database Links |
SwissProt: P01308 |
| Synonyms | Connecting Peptide |
| Research Area | Signaling transduction,Metabolism |
Share
