SKU(재고 관리 코드):ELK9588
Human P-Cadherin(Cadherin, Placental) ELISA Kit
Human P-Cadherin(Cadherin, Placental) ELISA Kit
Human P-Cadherin(Cadherin, Placental) ELISA Kit
Overview
Product name: | Human P-Cadherin(Cadherin, Placental) ELISA Kit |
Reactivity: | Human |
Alternative Names: | CDH3; CDHP; HJMD; PCAD; Cadherin 3; type 1 |
Assay Type: | Sandwich |
Sensitivity: | 37.50 pg/mL |
Standard: | 4000 pg/mL |
Detection Range: | 62.50-4000 pg/mL |
Sample Type: | serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids |
Assay Length: | 3.5h |
Research Area: | Signal Transduction;Neuroscience |
Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human P-Cadherin. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human P-Cadherin. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human P-Cadherin, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human P-Cadherin in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
Concentration (ng/mL) | OD | Corrected OD |
---|---|---|
4000.00 | 1.912 | 1.815 |
2000.00 | 1.579 | 1.482 |
1000.00 | 1.186 | 1.089 |
500.00 | 0.852 | 0.755 |
250.00 | 0.525 | 0.428 |
125.00 | 0.361 | 0.264 |
62.50 | 0.258 | 0.161 |
0.00 | 0.097 | 0.000 |
Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant P-Cadherin and the recovery rates were calculated by comparing the measured value to the expected amount of P-Cadherin in samples.
Matrix | Recovery range | Average |
---|---|---|
serum(n=5) | 80-97% | 88% |
EDTA plasma(n=5) | 93-101% | 97% |
Heparin plasma(n=5) | 92-106% | 99% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of P-Cadherin and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
---|---|---|---|---|
serum(n=5) | 89-96% | 90-99% | 95-106% | 87-101% |
EDTA plasma(n=5) | 79-86% | 87-103% | 84-97% | 88-97% |
Heparin plasma(n=5) | 95-106% | 83-98% | 79-93% | 81-96% |