1
/
의
1
ELK Biotechnology
SKU(재고 관리 코드):ELK6770
Mouse ART1(ADP Ribosyltransferase 1) ELISA Kit
Mouse ART1(ADP Ribosyltransferase 1) ELISA Kit
Mouse ART1(ADP Ribosyltransferase 1) ELISA Kit
Overview
| Product name: | Mouse ART1(ADP Ribosyltransferase 1) ELISA Kit |
| Reactivity: | Mouse |
| Alternative Names: | CD296; ART2; ARTC1; Mono(ADP-ribosyl)transferase 1; ADP-ribosyltransferase C2 and C3 toxin-like 1; GPI-linked NAD(P)(+)--arginine ADP-ribosyltransferase 1 |
| Assay Type: | Sandwich |
| Sensitivity: | 0.32 ng/mL |
| Standard: | 50 ng/mL |
| Detection Range: | 0.79-50 ng/mL |
| Sample Type: | Tissue homogenates and other biological fluids. |
| Assay Length: | 3.5h |
| Research Area: | Enzyme & Kinase; |
| Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse ART1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse ART1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse ART1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse ART1 in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 50.00 | 2.079 | 1.990 |
| 25.00 | 1.673 | 1.584 |
| 12.50 | 1.073 | 0.984 |
| 6.25 | 0.797 | 0.708 |
| 3.13 | 0.508 | 0.419 |
| 1.57 | 0.265 | 0.176 |
| 0.79 | 0.207 | 0.118 |
| 0.00 | 0.089 | 0.000 |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant ART1 and the recovery rates were calculated by comparing the measured value to the expected amount of ART1 in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 88-99% | 93% |
| EDTA plasma(n=5) | 86-98% | 92% |
| Heparin plasma(n=5) | 82-98% | 87% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ART1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 87-93% | 95-106% | 88-103% | 81-98% |
| EDTA plasma(n=5) | 86-93% | 93-101% | 86-97% | 90-101% |
| Heparin plasma(n=5) | 91-99% | 88-97% | 88-104% | 97-108% |