Overview
| Product name: | Mouse IL-27(Interleukin 27) ELISA Kit |
| Reactivity: | Mouse |
| Alternative Names: | IL-27; IL-27A; IL27p28; IL30; MGC71873; p28; |
| Assay Type: | Sandwich |
| Sensitivity: | 18.75 pg/mL |
| Standard: | 2000 pg/mL |
| Detection Range: | 31.25-2000 pg/mL |
| Sample Type: | serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids |
| Assay Length: | 3.5h |
| Research Area: | Immunology;Cancer |
| Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse IL-27. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse IL-27. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse IL-27, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse IL-27 in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 2000.00 | 2.135 | 2.054 |
| 1000.00 | 1.663 | 1.582 |
| 500.00 | 1.226 | 1.145 |
| 250.00 | 0.852 | 0.771 |
| 125.00 | 0.539 | 0.458 |
| 62.50 | 0.313 | 0.232 |
| 31.25 | 0.235 | 0.154 |
| 0.00 | 0.081 | 0.000 |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant IL-27 and the recovery rates were calculated by comparing the measured value to the expected amount of IL-27 in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 82-94% | 88% |
| EDTA plasma(n=5) | 95-107% | 101% |
| Heparin plasma(n=5) | 84-93% | 89% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of IL-27 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 79-93% | 94-106% | 83-97% | 93-102% |
| EDTA plasma(n=5) | 89-97% | 85-97% | 87-96% | 88-97% |
| Heparin plasma(n=5) | 91-97% | 81-93% | 89-103% | 82-91% |