Mouse SP-A1(Pulmonarysurfactant-associated protein A1) ELISA Kit
Mouse SP-A1(Pulmonarysurfactant-associated protein A1) ELISA Kit
Mouse SP-A1(Pulmonarysurfactant-associated protein A1) ELISA Kit
Overview
| Product name: | Mouse SP-A1(Pulmonarysurfactant-associated protein A1) ELISA Kit |
| Reactivity: | Mouse |
| Alternative Names: | MGC133365; PSAP; PSPA; SFTP1; SFTPA1 |
| Assay Type: | Sandwich |
| Sensitivity: | 0.19 ng/mL |
| Standard: | 20 ng/mL |
| Detection Range: | 0.31-20 ng/mL |
| Sample Type: | serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids |
| Assay Length: | 3.5h |
| Research Area: | Signal Transduction |
| Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse SP-A1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse SP-A1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse SP-A1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse SP-A1 in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 20.00 | 1.954 | 1.866 |
| 10.00 | 1.612 | 1.524 |
| 5.00 | 1.251 | 1.163 |
| 2.50 | 0.975 | 0.887 |
| 1.25 | 0.617 | 0.529 |
| 0.63 | 0.368 | 0.280 |
| 0.32 | 0.226 | 0.138 |
| 0.00 | 0.088 | 0.000 |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant SP-A1 and the recovery rates were calculated by comparing the measured value to the expected amount of SP-A1 in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 82-95% | 88% |
| EDTA plasma(n=5) | 87-95% | 91% |
| Heparin plasma(n=5) | 79-93% | 86% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of SP-A1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 82-96% | 92-103% | 90-99% | 89-102% |
| EDTA plasma(n=5) | 87-102% | 85-94% | 87-101% | 95-102% |
| Heparin plasma(n=5) | 89-98% | 95-103% | 97-103% | 82-94% |