FineTest
SKU(재고 관리 코드):EH5020
Human anti-cd11a antibody Elisa kit
Human anti-cd11a antibody Elisa kit
Product Name
Human anti-cd11a antibody Elisa kit
Alias
anti-cd11a antibody ELISA Kit
Detection Method
Indirect ELISA Sandwich
Application
anti-cd11a antibody Elisa kit allows for the in vitro quantitative determination of anti-cd11a antibody concentrations in serum, plasma, tissue homogenates and other biological fluids.
Size
96T
Range
10-640ng/ml
Sensitivity
< 6ng/ml
Species
Human
Standard Curve

Storage
2-8 ℃ for 6 months
Recovery
Matrices listed below were spiked with certain level of anti-cd11a antibody and the recovery rates were calculated by comparing the measured value to the expected amount of anti-cd11a antibody in samples.
|
Matrix |
Recovery range(%) |
Average(%) |
|
serum(n=5) |
85-102 |
92 |
|
EDTA plasma(n=5) |
86-99 |
94 |
|
heparin plasma(n=5) |
92-100 |
95 |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of anti-cd11a antibody and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
|
Sample |
1:2 |
1:4 |
1:8 |
|
serum(n=5) |
86-104% |
90-98% |
86-103% |
|
EDTA plasma(n=5) |
84-95% |
82-96% |
82-100% |
|
heparin plasma(n=5) |
83-99% |
83-94% |
82-100% |
CV(%)
Intra-Assay: CV<8%
Inter-Assay: CV<10%
Note
For Research Use Only
Share