제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMA930Hu

Magnetic Luminex Assay Kit for Extracellular Signal Regulated Kinase 2 (ERK2) ,etc.

Magnetic Luminex Assay Kit for Extracellular Signal Regulated Kinase 2 (ERK2) ,etc.

Detection range
Size
Sensitivity

Product No.

LMA930Hu

Organism Species

Homo sapiens (Human).

Sample Type

serum, plasma, tissue homogenates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

2.93-3000pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.977 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex.

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Extracellular Signal Regulated Kinase 2 (ERK2) ,etc..
No significant cross-reactivity or interference between Extracellular Signal Regulated Kinase 2 (ERK2) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Extracellular Signal Regulated Kinase 2 (ERK2) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Extracellular Signal Regulated Kinase 2 (ERK2) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 95-104 101
EDTA plasma(n=5) 98-105 101
heparin plasma(n=5) 78-92 84

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Extracellular Signal Regulated Kinase 2 (ERK2) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Extracellular Signal Regulated Kinase 2 (ERK2) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Extracellular Signal Regulated Kinase 2 (ERK2) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-94% 91-102% 92-104% 91-99%
EDTA plasma(n=5) 92-99% 83-103% 82-90% 98-105%
heparin plasma(n=5) 83-91% 86-93% 87-96% 89-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:ERK2) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Cellular and Molecular Neurobiology Hypericum Perforatum Hydroalcoholic Extract Mitigates Motor Dysfunction and is Neuroprotective in Intrastriatal 6-Hydroxydopamine Rat Model of Parkinson’s Disease Pubmed:26119304
Graefe's Archive for Clinical and Experimental Ophthalmology Role of RhoA/MERK1/ERK1/2/iNOS signaling in ocular ischemic syndrome pubmed:27538909
International Journal of Reproductive Medicine Gonadotropin Stimulation Has Only a Limited Effect on the Concentration of Follicular Fluid Signalling Proteins: An Antibody Array Analysis 33575317
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
APA930Hu01 Active Extracellular Signal Regulated Kinase 2 (ERK2) Cell culture; Activity Assays.
RPA930Hu01 Recombinant Extracellular Signal Regulated Kinase 2 (ERK2) Positive Control; Immunogen; SDS-PAGE; WB.
RPA930Hu02 Recombinant Extracellular Signal Regulated Kinase 2 (ERK2) Positive Control; Immunogen; SDS-PAGE; WB.
PAA930Hu01 Polyclonal Antibody to Extracellular Signal Regulated Kinase 2 (ERK2) WB; IHC; ICC; IP.
PAA930Hu02 Polyclonal Antibody to Extracellular Signal Regulated Kinase 2 (ERK2) WB; IHC; ICC; IP.
CAA930Hu01 Anti-Extracellular Signal Regulated Kinase 2 (ERK2) Polyclonal Antibody Loading Control of WB
MAA930Hu23 Monoclonal Antibody to Extracellular Signal Regulated Kinase 2 (ERK2) WB; IHC; ICC; IP.
MAA930Hu22 Monoclonal Antibody to Extracellular Signal Regulated Kinase 2 (ERK2) WB; IHC; ICC; IP.
MAA930Hu24 Monoclonal Antibody to Extracellular Signal Regulated Kinase 2 (ERK2) WB; IHC; ICC; IP.
CAA930Hu22 Anti-Extracellular Signal Regulated Kinase 2 (ERK2) Monoclonal Antibody Loading Control of WB
MAA930Hu25 Monoclonal Antibody to Extracellular Signal Regulated Kinase 2 (ERK2) WB; IHC; ICC; IP.
MAA930Hu21 Monoclonal Antibody to Extracellular Signal Regulated Kinase 2 (ERK2) WB; IHC; ICC; IP.
MEA930Hu Mini Samples ELISA Kit for Extracellular Signal Regulated Kinase 2 (ERK2) Enzyme-linked immunosorbent assay for Antigen Detection.
SEA930Hu ELISA Kit for Extracellular Signal Regulated Kinase 2 (ERK2) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA930Hu Magnetic Luminex Assay Kit for Extracellular Signal Regulated Kinase 2 (ERK2) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기