Cloud-clone
SKU(재고 관리 코드):LMB710Hu
Magnetic Luminex Assay Kit for Glycocalicin (GC) ,etc.
Magnetic Luminex Assay Kit for Glycocalicin (GC) ,etc.
Product No.
LMB710Hu
Organism Species
Homo sapiens (Human).
Sample Type
Plasma
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.98-1000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.327 pg/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex.
Specificity
This assay has high sensitivity and excellent specificity for detection of Glycocalicin (GC) ,etc..
No significant cross-reactivity or interference between Glycocalicin (GC) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Glycocalicin (GC) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Glycocalicin (GC) ,etc. in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 79-94 | 85 |
| EDTA plasma(n=5) | 78-93 | 85 |
| heparin plasma(n=5) | 80-103 | 89 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glycocalicin (GC) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glycocalicin (GC) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glycocalicin (GC) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 96-105% | 95-103% | 93-101% | 84-96% |
| EDTA plasma(n=5) | 83-96% | 90-98% | 78-92% | 78-90% |
| heparin plasma(n=5) | 84-97% | 94-101% | 86-96% | 86-93% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:GC) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
| Magazine | Citations |
| Nanoscale. | A factor VIII-derived peptide enables von Willebrand factor (VWF)-binding of artificial platelet nanoconstructs without interfering with VWF-adhesion of natural platelets Pubmed:Pmc4300948 |
| Thrombosis Research | Factors associated with the platelet count in patients with chronic hepatitis C Pubmed:25728497 |
| Proteomics Clinical Applications | iTRAQ‐Based Proteomic Analysis Reveals Protein Profile in Plasma from Children with Autism Pubmed:29274201 |
| Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
| RPB710Hu01 | Recombinant Glycocalicin (GC) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAB710Hu01 | Polyclonal Antibody to Glycocalicin (GC) | WB; IHC; ICC; IP. |
| LAB710Hu71 | Biotin-Linked Polyclonal Antibody to Glycocalicin (GC) | WB; IHC; ICC. |
| SEB710Hu | ELISA Kit for Glycocalicin (GC) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| LMB710Hu | Magnetic Luminex Assay Kit for Glycocalicin (GC) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
Share