제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMH947Hu

Magnetic Luminex Assay Kit for Guanylate Cyclase 1 Beta 3 (GUCY1b3) ,etc.

Magnetic Luminex Assay Kit for Guanylate Cyclase 1 Beta 3 (GUCY1b3) ,etc.

Detection range
Size
Sensitivity

Product No.

LMH947Hu

Organism Species

Homo sapiens (Human).

Sample Type

Serum, plasma, tissue homogenates and other biological fluids.

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.01-10ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.003 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Guanylate Cyclase 1 Beta 3 (GUCY1b3) ,etc..
No significant cross-reactivity or interference between Guanylate Cyclase 1 Beta 3 (GUCY1b3) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Guanylate Cyclase 1 Beta 3 (GUCY1b3) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Guanylate Cyclase 1 Beta 3 (GUCY1b3) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 92-101 95
EDTA plasma(n=5) 79-104 95
heparin plasma(n=5) 80-91 87

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Guanylate Cyclase 1 Beta 3 (GUCY1b3) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Guanylate Cyclase 1 Beta 3 (GUCY1b3) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Guanylate Cyclase 1 Beta 3 (GUCY1b3) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 94-102% 78-102% 95-105% 95-103%
EDTA plasma(n=5) 87-101% 96-103% 80-93% 90-104%
heparin plasma(n=5) 80-105% 78-95% 79-93% 88-95%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:GUCY1b3) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
High Altitude Medicine & Biology Elevated Vasodilatory Cyclases and Shorter Telomere Length Contribute to High-Altitude Pulmonary Edema 10.1089:ham.2017.0136
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPH947Hu01 Recombinant Guanylate Cyclase 1 Beta 3 (GUCY1b3) Positive Control; Immunogen; SDS-PAGE; WB.
PAH947Hu01 Polyclonal Antibody to Guanylate Cyclase 1 Beta 3 (GUCY1b3) WB; ICC; IHC-P; IHC-F; ELISA.
MAH947Hu21 Monoclonal Antibody to Guanylate Cyclase 1 Beta 3 (GUCY1b3) WB; IHC; ICC; IP.
SEH947Hu ELISA Kit for Guanylate Cyclase 1 Beta 3 (GUCY1b3) Enzyme-linked immunosorbent assay for Antigen Detection.
LMH947Hu Magnetic Luminex Assay Kit for Guanylate Cyclase 1 Beta 3 (GUCY1b3) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기