제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMF415Hu

Magnetic Luminex Assay Kit for Endothelin 2 (EDN2) ,etc.

Magnetic Luminex Assay Kit for Endothelin 2 (EDN2) ,etc.

Detection range
Size
Sensitivity

Product No.

LMF415Hu

Organism Species

Homo sapiens (Human).

Sample Type

Serum, plasma and other biological fluids.

Test Method

Competitive Inhibition

Assay Length

1.5h

Detection Range

0.98-1000pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.327 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Endothelin 2 (EDN2) ,etc..
No significant cross-reactivity or interference between Endothelin 2 (EDN2) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Endothelin 2 (EDN2) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Endothelin 2 (EDN2) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 81-102 88
EDTA plasma(n=5) 87-104 94
heparin plasma(n=5) 87-101 96

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Endothelin 2 (EDN2) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Endothelin 2 (EDN2) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Endothelin 2 (EDN2) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 83-94% 94-102% 78-98% 82-92%
EDTA plasma(n=5) 86-94% 80-101% 78-101% 95-104%
heparin plasma(n=5) 79-93% 86-94% 79-95% 96-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:EDN2) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPF415Hu01 Recombinant Endothelin 2 (EDN2) Positive Control; Immunogen; SDS-PAGE; WB.
PAF415Hu01 Polyclonal Antibody to Endothelin 2 (EDN2) WB; IHC; ICC; IP.
MAF415Hu21 Monoclonal Antibody to Endothelin 2 (EDN2) WB; IHC; ICC; IP.
CEF415Hu ELISA Kit for Endothelin 2 (EDN2) Enzyme-linked immunosorbent assay for Antigen Detection.
LMF415Hu Magnetic Luminex Assay Kit for Endothelin 2 (EDN2) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기