Magnetic Luminex Assay Kit for Interleukin 32 (IL32) ,etc.
Magnetic Luminex Assay Kit for Interleukin 32 (IL32) ,etc.
Product No.
LMB802Hu
Organism Species
Homo sapiens (Human).
Sample Type
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.98-1000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.327 pg/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Interleukin 32 (IL32) ,etc..
No significant cross-reactivity or interference between Interleukin 32 (IL32) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Interleukin 32 (IL32) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Interleukin 32 (IL32) ,etc. in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 97-104 | 101 |
EDTA plasma(n=5) | 97-105 | 101 |
heparin plasma(n=5) | 82-101 | 92 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 32 (IL32) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 32 (IL32) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interleukin 32 (IL32) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 96-104% | 97-105% | 93-102% | 90-97% |
EDTA plasma(n=5) | 80-96% | 79-93% | 80-91% | 98-105% |
heparin plasma(n=5) | 89-98% | 87-94% | 80-103% | 83-97% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:IL32) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
Magazine | Citations |
Lupus. | Three cases of lupus nephritis patients with serum interleukin-32γ detection Pubmed:24879659 |
Tumour Biol | Clinical significance of serum interleukin-29, interleukin-32, and tumor necrosis factor alpha levels in patients with gastric cancer PubMed: 26219901 |
Biomedical Reports | Calprotectin in serum and zonulin in serum and feces are elevated after introduction of a diet with lower carbohydrate content and higher fiber, fat and protein contents. pubmed:28413639 |
Arab Journal of Gastroenterology | Role of several cytokines and adhesion molecules in the diagnosis and prediction of survival ofhepatocellular carcinoma. pubmed:27916547 |
ResearchGate | SERUM INTERLEUKIN-32 (IL-32) LEVELS MAY HAVE DIAGNOSTIC AND PROGNOSTIC ROLES IN PATIENTS WITH... doi:10.19193/0393-6384_2017_4_091 |
Biomedical Reports | Calprotectin in serum and zonulin in serum and feces are elevated after introduction of a diet with lower carbohydrate content and higher fiber, fat and protein contents 10.3892/br.2017.865 |
Journal of Diabetes & Metabolism | High Fiber Fat and Protein Contents Lead to Increased Satiety Reduced Sweet Cravings and Decreased Gastrointestinal Symptoms Independently of Anthropometric Hormonal and Metabolic Factors 10.4172/2155-6156.1000733 |
IL-31, IL-32 and IL-33 may Serve as Diagnosis Biomarkers in Gastric Cancer |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
RPB802Hu02 | Recombinant Interleukin 32 (IL32) | Positive Control; Immunogen; SDS-PAGE; WB. |
APB802Hu01 | Active Interleukin 32 (IL32) | Cell culture; Activity Assays. |
APB802Hu02 | Active Interleukin 32 (IL32) | Cell culture; Activity Assays. |
RPB802Hu01 | Recombinant Interleukin 32 (IL32) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAB802Hu01 | Polyclonal Antibody to Interleukin 32 (IL32) | WB; IHC; ICC; IP. |
PAB802Hu02 | Polyclonal Antibody to Interleukin 32 (IL32) | WB; IHC; ICC; IP. |
MAB802Hu22 | Monoclonal Antibody to Interleukin 32 (IL32) | WB; IHC; ICC; IP. |
SEB802Hu | ELISA Kit for Interleukin 32 (IL32) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCB802Hu | CLIA Kit for Interleukin 32 (IL32) | Chemiluminescent immunoassay for Antigen Detection. |
LMB802Hu | Magnetic Luminex Assay Kit for Interleukin 32 (IL32) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
PGB802Hu01 | Primer Pair for Interleukin 32 (IL32) | PCR |