제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMC007Mu

Magnetic Luminex Assay Kit for Interleukin 34 (IL34) ,etc.

Magnetic Luminex Assay Kit for Interleukin 34 (IL34) ,etc.

Detection range
Size
Sensitivity

Product No.

LMC007Mu

Organism Species

Mus musculus (Mouse).

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.49-500pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.163 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Interleukin 34 (IL34) ,etc..
No significant cross-reactivity or interference between Interleukin 34 (IL34) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Interleukin 34 (IL34) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Interleukin 34 (IL34) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 85-99 89
EDTA plasma(n=5) 78-98 91
heparin plasma(n=5) 84-96 90

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 34 (IL34) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 34 (IL34) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interleukin 34 (IL34) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 97-105% 85-99% 91-103% 87-95%
EDTA plasma(n=5) 78-91% 87-105% 80-104% 81-104%
heparin plasma(n=5) 88-95% 82-105% 94-101% 95-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:IL34) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
J Int Med Res. Increased Serum Interleukin-34 in Patients with Coronary Artery Disease PubMed: 23206468
Transplantation IL-34 inhibits acute rejection of rat liver transplantation by inducing Kupffer cell M2 polarization Pubmed:29570162
cyberleninka КЛИНИКО-ЭПИДЕМИОЛОГИЧЕСКАЯ ХАРАКТЕРИСТИКА И ОСОБЕННОСТИ БАЛЛАНСА ЦИТОКИНОВ ПРИ КЛЕЩЕВОМ ЭНЦЕФАЛИТЕ В …
Revista da Associacao Medica Brasileira A comparison of IL-17 and IL-34 concentrations in the cerebrospinal fluid of patients with acute inflammatory demyelinating neuropathy and chronic …
Rev Assoc Med Bras A comparison of IL-17 and IL-34 concentrations in the cerebrospinal fluid of patients with acute inflammatory demyelinating neuropathy and chronic?¡­ 33295414
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPC007Mu02 Recombinant Interleukin 34 (IL34) Positive Control; Immunogen; SDS-PAGE; WB.
APC007Mu61 Active Interleukin 34 (IL34) Cell culture; Activity Assays.
EPC007Mu61 Eukaryotic Interleukin 34 (IL34) Positive Control; Immunogen; SDS-PAGE; WB.
RPC007Mu01 Recombinant Interleukin 34 (IL34) Positive Control; Immunogen; SDS-PAGE; WB.
APC007Mu01 Active Interleukin 34 (IL34) Cell culture; Activity Assays.
PAC007Mu01 Polyclonal Antibody to Interleukin 34 (IL34) WB; IHC; ICC; IP.
PAC007Mu02 Polyclonal Antibody to Interleukin 34 (IL34) WB; IHC; ICC; IP.
LAC007Mu71 Biotin-Linked Polyclonal Antibody to Interleukin 34 (IL34) WB; IHC; ICC.
MAC007Mu21 Monoclonal Antibody to Interleukin 34 (IL34) WB; IHC; ICC; IP.
MEC007Mu Mini Samples ELISA Kit for Interleukin 34 (IL34) Enzyme-linked immunosorbent assay for Antigen Detection.
SEC007Mu ELISA Kit for Interleukin 34 (IL34) Enzyme-linked immunosorbent assay for Antigen Detection.
SCC007Mu CLIA Kit for Interleukin 34 (IL34) Chemiluminescent immunoassay for Antigen Detection.
LMC007Mu Magnetic Luminex Assay Kit for Interleukin 34 (IL34) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기