제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMB342Mi

Magnetic Luminex Assay Kit for Actin Alpha 2, Smooth Muscle (ACTa2) ,etc.

Magnetic Luminex Assay Kit for Actin Alpha 2, Smooth Muscle (ACTa2) ,etc.

Detection range
Size
Sensitivity

Product No.

LMB342Mi

Organism Species

Homo sapiens (Human), Mus musculus (Mouse), Rattus norvegicus (Rat).

Sample Type

Tissue homogenates, cell lysates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.49-500ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.163 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity for detection of Actin Alpha 2, Smooth Muscle (ACTa2) ,etc..
100% cross-reactivity of Actin Alpha 2, Smooth Muscle (ACTa2) ,etc. was observed among Human, Mouse, Rat.

Recovery

Matrices listed below were spiked with certain level of recombinant Actin Alpha 2, Smooth Muscle (ACTa2) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Actin Alpha 2, Smooth Muscle (ACTa2) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 81-104 87
EDTA plasma(n=5) 81-105 88
heparin plasma(n=5) 79-89 85

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Actin Alpha 2, Smooth Muscle (ACTa2) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Actin Alpha 2, Smooth Muscle (ACTa2) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Actin Alpha 2, Smooth Muscle (ACTa2) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 81-93% 86-94% 96-104% 90-104%
EDTA plasma(n=5) 85-105% 97-105% 80-101% 89-103%
heparin plasma(n=5) 86-101% 88-95% 86-94% 92-99%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:ACTa2) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Cell Mol Immunol  Toxoplasma gondii GRA15II effector-induced M1 cells ameliorate liver fibrosis in mice infected with Schistosomiasis japonica Pubmed:27157496
NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY Effects of repeated increasing doses of cisplatin as models of acute kidney injury and chronic kidney disease in rats Pubmed: 32936352
Brazilian Journal of Pharmaceutical Sciences Hesperidin inhibits the epithelial to mesenchymal transition induced by transforming growth factor-β1 in A549 cells through Smad signaling in the cytoplasm
Structural Changes and Detection of Liver Fibrosis¨CRelated Protein Levels in Coculture of Alveolar Echinococcosis-Protoscoleces and Human Hepatic Stellate cells
Parasit Vectors Structural changes and expression of hepatic fibrosis-related proteins in coculture of Echinococcus multilocularis protoscoleces and human hepatic stellate … 34857049
Clinical and Translational Medicine NOX5 mediates the crosstalk between tumor cells and cancer‐associated fibroblasts via regulating cytokine network 34459125
Catalog No. Related products for research use of Homo sapiens (Human), Mus musculus (Mouse), Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPB342Mi01 Recombinant Actin Alpha 2, Smooth Muscle (ACTa2) Positive Control; Immunogen; SDS-PAGE; WB.
CAB342Mi01 Anti-Actin Alpha 2, Smooth Muscle (ACTa2) Polyclonal Antibody Loading Control of WB.
PAB342Mi01 Polyclonal Antibody to Actin Alpha 2, Smooth Muscle (ACTa2) WB; IHC; ICC; IP.
MAB342Mi21 Monoclonal Antibody to Actin Alpha 2, Smooth Muscle (ACTa2) WB; IHC; ICC; IP.
MAB342Mi22 Monoclonal Antibody to Actin Alpha 2, Smooth Muscle (ACTa2) WB; IHC; ICC; IP.
MAB342Mi23 Monoclonal Antibody to Actin Alpha 2, Smooth Muscle (ACTa2) WB; IHC; ICC; IP.
MAB342Mi24 Monoclonal Antibody to Actin Alpha 2, Smooth Muscle (ACTa2) WB; IHC; ICC; IP.
MAB342Mi25 Monoclonal Antibody to Actin Alpha 2, Smooth Muscle (ACTa2) WB; IHC; ICC; IP.
SEB342Mi ELISA Kit for Actin Alpha 2, Smooth Muscle (ACTa2) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB342Mi Magnetic Luminex Assay Kit for Actin Alpha 2, Smooth Muscle (ACTa2) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기