제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMA831Hu

Magnetic Luminex Assay Kit for Thrombin/Antithrombin Complex (TAT) ,etc.

Magnetic Luminex Assay Kit for Thrombin/Antithrombin Complex (TAT) ,etc.

Detection range
Size
Sensitivity

Product No.

LMA831Hu

Organism Species

Homo sapiens (Human).

Sample Type

Plasma

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.39-400pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.13 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Thrombin/Antithrombin Complex (TAT) ,etc..
No significant cross-reactivity or interference between Thrombin/Antithrombin Complex (TAT) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Thrombin/Antithrombin Complex (TAT) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Thrombin/Antithrombin Complex (TAT) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 89-96 93
EDTA plasma(n=5) 83-102 88
heparin plasma(n=5) 98-105 102

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Thrombin/Antithrombin Complex (TAT) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Thrombin/Antithrombin Complex (TAT) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Thrombin/Antithrombin Complex (TAT) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 93-103% 83-97% 94-104% 95-102%
EDTA plasma(n=5) 78-101% 79-94% 83-101% 86-103%
heparin plasma(n=5) 78-104% 82-102% 90-98% 99-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:TAT) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Magazine Citations
IUBMB LIFE Genetic repression of mouse VEGF expression regulates coagulation cascade. PubMed: 21086498
Thrombosis Research Treatment with unfractionated heparin attenuates coagulation and inflammation in endotoxemic mice ScienceDirect: S0049384811004166
Journal of Thrombosis and Haemostasis High sCD40L levels early after trauma are associated with enhanced shock, sympathoadrenal activation, tissue and endothelial damage, coagulopathy and mortality Wiley: source
3 Tissue factor and PAR1 promote microbiota-induced intestinal vascular remodelling Nature: 20120329
Am J Respir Cell Mol Bio Prolonged Exposure to Sphingosine 1–Phosphate Receptor-1 Agonists Exacerbates Vascular Leak, Fibrosis, and Mortality after Lung Injury PubMed: PMC2993087
PLoS One Host Defense Peptides of Thrombin Modulate Inflammation and Coagulation in Endotoxin-Mediated Shock and Pseudomonas aeruginosa Sepsis PubMed: PMC3521733
Haemetology Clinical impact of factor V Leiden, prothrombin G20210A, and MTHFR C677T mutations among sickle cell disease patients of Central India Pubmed: 23992124
Am J Transl Res. Selected hemostatic parameters in patients with pancreatic tumors. Pubmed:Pmc4297344
PLOS ONE TFPI1 Mediates Resistance to Doxorubicin in Breast Cancer Cells by Inducing a Hypoxic-Like Response Pubmed:24489651
Leukemia Novel evidence that crosstalk between the complement, coagulation and fibrinolysis proteolytic cascades is involved in mobilization of hematopoietic stem/progenitor cells (HSPCs) Pubmed:24667943
Anesthesia &amp; Analgesia Thrombomodulin Improved Liver Injury, Coagulopathy, and Mortality in an Experimental Heatstroke Model in Mice Pubmed:24781566
Cell Transplantation Evidence of a Pivotal Role for the Distal Part of the Complement Cascade in the Diurnal Release of Hematopoietic Stem Cells Into Peripheral Blood Pubmed:26087465
European Journal of Pharmacology (S)YS-51, a novel isoquinoline alkaloid, attenuates obesity-associated non-alcoholic fatty liver disease in mice by suppressing lipogenesis, inflammation and coaCavia (Guinea pig )lation Pubmed:27343380
J Thromb Haemost. Coagulation factor XI vaccination: an alternative strategy to prevent thrombosis. pubmed:27813324
Blood Cells, Inflammation and Infection Nebulized Heparin Attenuates Pulmonary Coagulopathy and Inflammation through Alveolar Macrophages in a Rat Model of Acute Lung Injury pubmed:29202212
SCIENCE TRANSLATIONAL MEDICINE Platelet-localized FXI promotes a vascular coagulation-inflammatory circuit in arterial hypertension pubmed:28148841
32 Activated TAFI Promotes the Development of Chronic Thromboembolic Pulmonary Hypertension: A Possible Novel Therapeutic Target pubmed:28289017
Thrombosis andHaemostasis Nebulized anti-coagulants as a therapy for acute lung injury and acute respiratory distress syndrome Pubmed: 29202212
Thrombosis Research The circadian rhythm of selected parameters of the hemostasis system in healthy people
Experimental Neurobiology Transduced Tat-aldose Reductase Protects Hippocampal Neuronal Cells against Oxidative Stress-induced Damage Pubmed: 31698553
LIVER TRANSPLANTATION The impact of dabigatran treatment on sinusoidal protection against hepatic ischemia‐reperfusion injury in mice Pubmed: 33108682
Am J Physiol Heart Circ Physiol Doxorubicin contributes to thrombus formation and vascular injury via enhancing platelet functions in vivo Pubmed: 32469636
Intensive Care Medicine Experimental Preservation of renal endothelial integrity and reduction of renal edema by aprotinin does not preserve renal perfusion and function following experimental … 34169407
Intensive Care Med Exp Complement factor D is linked to platelet activation in human and rodent sepsis 34396466
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
EPA831Hu61 Eukaryotic Thrombin/Antithrombin Complex (TAT) Positive Control; Immunogen; SDS-PAGE; WB.
RPA831Hu01 Recombinant Thrombin/Antithrombin Complex (TAT) Positive Control; Immunogen; SDS-PAGE; WB.
MAA831Hu21 Monoclonal Antibody to Thrombin/Antithrombin Complex (TAT) WB
MAA831Hu24 Monoclonal Antibody to Thrombin/Antithrombin Complex (TAT) WB; IHC; ICC; IP.
MAA831Hu25 Monoclonal Antibody to Thrombin/Antithrombin Complex (TAT) WB; IHC; ICC; IP.
MAA831Hu22 Monoclonal Antibody to Thrombin/Antithrombin Complex (TAT) WB; IHC; ICC; IP.
MAA831Hu23 Monoclonal Antibody to Thrombin/Antithrombin Complex (TAT) WB; IHC; ICC; IP.
SEA831Hu ELISA Kit for Thrombin/Antithrombin Complex (TAT) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA831Hu Magnetic Luminex Assay Kit for Thrombin/Antithrombin Complex (TAT) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기