Cloud-clone

SKU(재고 관리 코드):LMC585Hu

Magnetic Luminex Assay Kit for Urocortin 2 (UCN2) ,etc.

Magnetic Luminex Assay Kit for Urocortin 2 (UCN2) ,etc.

Detection range
Size
Sensitivity

Product No.

LMC585Hu

Organism Species

Homo sapiens (Human).

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.49-500pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.163 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Urocortin 2 (UCN2) ,etc..
No significant cross-reactivity or interference between Urocortin 2 (UCN2) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Urocortin 2 (UCN2) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Urocortin 2 (UCN2) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-99 81
EDTA plasma(n=5) 81-104 95
heparin plasma(n=5) 97-105 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Urocortin 2 (UCN2) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Urocortin 2 (UCN2) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Urocortin 2 (UCN2) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 83-90% 98-105% 93-101% 78-97%
EDTA plasma(n=5) 80-95% 95-103% 85-99% 97-104%
heparin plasma(n=5) 88-102% 80-95% 80-96% 96-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:UCN2) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

 

     

    INCREMENT SERVICES

    Magazine Citations
    Clin Chem. High-Sensitivity Sandwich ELISA for Plasma NT-proUcn2: Plasma Concentrations and Relationship to Mortality in Heart Failure. Pubmed:27127183
    Clinica Chimica Acta Urocortins: Actions in health and heart failure pubmed:28887029
    Cardiovascular Research Urocortin-2 improves right ventricular function and attenuates pulmonary arterial hypertension Pubmed:29584808
    Journal of Neuroendocrinology Glucocorticoid withdrawal affects stress‐induced changes in urocortin 2 gene expression in the rat adrenal medulla and brain Pubmed:29604138
    High Blood Press Cardiovasc Prev Evaluation of Serum Urocortin 2 Levels in Patients with Hypertension Pubmed: 31925709
    CURRENT PROBLEMS IN CARDIOLOGY Urocortin-2 in acute heart failure: role as a marker of volume overload and pulmonary hypertension 33994037
    Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
    RPC585Hu01 Recombinant Urocortin 2 (UCN2) Positive Control; Immunogen; SDS-PAGE; WB.
    PAC585Hu01 Polyclonal Antibody to Urocortin 2 (UCN2) WB,IHC
    LAC585Hu71 Biotin-Linked Polyclonal Antibody to Urocortin 2 (UCN2) WB; IHC; ICC.
    LAC585Hu81 FITC-Linked Polyclonal Antibody to Urocortin 2 (UCN2) WB; IHC; ICC; IF.
    MAC585Hu24 Monoclonal Antibody to Urocortin 2 (UCN2) WB; IHC; ICC; IP.
    MAC585Hu25 Monoclonal Antibody to Urocortin 2 (UCN2) WB; IHC; ICC; IP.
    MAC585Hu22 Monoclonal Antibody to Urocortin 2 (UCN2) WB
    MAC585Hu21 Monoclonal Antibody to Urocortin 2 (UCN2) WB; IHC; ICC; IP.
    MAC585Hu23 Monoclonal Antibody to Urocortin 2 (UCN2) WB; IHC; ICC; IP.
    LAC585Hu72 Biotin-Linked Monoclonal Antibody to Urocortin 2 (UCN2) WB; IHC; ICC.
    HEC585Hu High Sensitive ELISA Kit for Urocortin 2 (UCN2) Enzyme-linked immunosorbent assay for Antigen Detection.
    SEC585Hu ELISA Kit for Urocortin 2 (UCN2) Enzyme-linked immunosorbent assay for Antigen Detection.
    LMC585Hu Magnetic Luminex Assay Kit for Urocortin 2 (UCN2) ,etc. Magnetic Luminex Assay for Antigen Detection.
    PSC585Hu01 Antibody Pair for Urocortin 2 (UCN2) ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays.
    KSC585Hu01 ELISA Kit DIY Materials for Urocortin 2 (UCN2) Main materials for "Do It (ELISA Kit) Yourself".
    전체 세부 정보 보기