SKU(재고 관리 코드):LMB074Bo
Magnetic Luminex Assay Kit for Polymeric Immunoglobulin Receptor (PIGR) ,etc.
Magnetic Luminex Assay Kit for Polymeric Immunoglobulin Receptor (PIGR) ,etc.
Product No.
LMB074Bo
Organism Species
Bos taurus; Bovine (Cattle).
Sample Type
Serum, plasma and other biological fluids.
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.04-40ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.013 ng/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Polymeric Immunoglobulin Receptor (PIGR) ,etc..
No significant cross-reactivity or interference between Polymeric Immunoglobulin Receptor (PIGR) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Polymeric Immunoglobulin Receptor (PIGR) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Polymeric Immunoglobulin Receptor (PIGR) ,etc. in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 86-94 | 90 |
EDTA plasma(n=5) | 99-105 | 102 |
heparin plasma(n=5) | 92-101 | 96 |
sodium citrate plasma(n=5) | 84-95 | 91 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Polymeric Immunoglobulin Receptor (PIGR) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Polymeric Immunoglobulin Receptor (PIGR) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Polymeric Immunoglobulin Receptor (PIGR) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 92-105% | 95-103% | 89-98% | 91-98% |
EDTA plasma(n=5) | 84-91% | 79-94% | 78-90% | 94-102% |
heparin plasma(n=5) | 80-91% | 88-102% | 80-90% | 87-101% |
sodium citrate plasma(n=5) | 83-95% | 83-105% | 97-105% | 80-95% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:PIGR) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
Magazine | Citations |
Journal of Proteome Research | Sputum proteomics identifies elevated PIGR levels in smokers and mild to moderate COPD ACS: pr2006395 |
Molecular & Cellular Proteomics | Integrated Proteomic Profiling of Cell Line Conditioned Media and Pancreatic Juice for the Identification of Pancreatic Cancer Biomarkers PubMed: PMC3205865 |
BMC Complementary and Alternative Medicine | Identification of plasma protein markers common to patients with malignant tumour and Abnormal Savda in Uighur medicine: a prospective clinical study Pubmed:25652121 |
British Journal of Cancer | Identification of a novel serum biomarker for pancreatic cancer, C4b-binding protein α-chain (C4BPA) by quantitative proteomic analysis using tandem mass tags. pubmed:27657339 |