제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMB309Hu

Magnetic Luminex Assay Kit for Pleiotrophin (PTN) ,etc.

Magnetic Luminex Assay Kit for Pleiotrophin (PTN) ,etc.

Detection range
Size
Sensitivity

Product No.

LMB309Hu

Organism Species

Homo sapiens (Human).

Sample Type

Serum, plasma, tissue homogenates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

1.95-2000pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.65 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Pleiotrophin (PTN) ,etc..
No significant cross-reactivity or interference between Pleiotrophin (PTN) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Pleiotrophin (PTN) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Pleiotrophin (PTN) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 93-105 97
EDTA plasma(n=5) 78-90 83
heparin plasma(n=5) 96-104 99
sodium citrate plasma(n=5) 85-97 89

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Pleiotrophin (PTN) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Pleiotrophin (PTN) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Pleiotrophin (PTN) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 86-101% 92-101% 83-93% 78-94%
EDTA plasma(n=5) 80-101% 83-98% 78-103% 88-99%
heparin plasma(n=5) 92-104% 84-92% 81-96% 86-94%
sodium citrate plasma(n=5) 81-93% 91-103% 91-105% 92-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:PTN) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Oncogene Suppression of lung adenocarcinoma through menin and polycomb gene-mediated repression of growth factor pleiotrophinMenin suppresses lung cancer through PTN Nature: 2009273
PLOS ONE The Effects of Pleiotrophin in Proliferative Diabetic Retinopathy Pubmed:25617851
Infect Immun.  Depletion of Phagocytic Cells during Nonlethal Plasmodium yoelii Infection Causes Severe Malaria Characterized by Acute Renal Failure in Mice. Pubmed:26755155
In Vivo Evaluation of Serum Biomarkers (FGF-2, HGF, MIF and PTN) in Patients With Testicular Germ Cell Cancer Pubmed: 31662522
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
APB309Hu01 Active Pleiotrophin (PTN) Cell culture; Activity Assays.
RPB309Hu02 Recombinant Pleiotrophin (PTN) Positive Control; Immunogen; SDS-PAGE; WB.
APB309Hu61 Active Pleiotrophin (PTN) Cell culture; Activity Assays.
RPB309Hu01 Recombinant Pleiotrophin (PTN) Positive Control; Immunogen; SDS-PAGE; WB.
EPB309Hu61 Eukaryotic Pleiotrophin (PTN) Positive Control; Immunogen; SDS-PAGE; WB.
PAB309Hu06 Polyclonal Antibody to Pleiotrophin (PTN) WB; IHC; ICC; IP.
PAB309Hu02 Polyclonal Antibody to Pleiotrophin (PTN) WB; IHC; ICC; IP.
PAB309Hu01 Polyclonal Antibody to Pleiotrophin (PTN) WB; IHC; ICC; IP.
LAB309Hu81 FITC-Linked Polyclonal Antibody to Pleiotrophin (PTN) WB; IHC; ICC; IF.
LAB309Hu71 Biotin-Linked Polyclonal Antibody to Pleiotrophin (PTN) WB; IHC; ICC.
MAB309Hu22 Monoclonal Antibody to Pleiotrophin (PTN) WB; IHC; ICC; IP.
SEB309Hu ELISA Kit for Pleiotrophin (PTN) Enzyme-linked immunosorbent assay for Antigen Detection.
SCB309Hu CLIA Kit for Pleiotrophin (PTN) Chemiluminescent immunoassay for Antigen Detection.
LMB309Hu Magnetic Luminex Assay Kit for Pleiotrophin (PTN) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기