제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMB225Hu

Magnetic Luminex Assay Kit for Cluster Of Differentiation 56 (CD56) ,etc.

Magnetic Luminex Assay Kit for Cluster Of Differentiation 56 (CD56) ,etc.

Detection range
Size
Sensitivity

Product No.

LMB225Hu

Organism Species

Homo sapiens (Human).

Sample Type

Serum, plasma, tissue homogenatesand other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.1-100ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.033 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Cluster Of Differentiation 56 (CD56) ,etc..
No significant cross-reactivity or interference between Cluster Of Differentiation 56 (CD56) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Cluster Of Differentiation 56 (CD56) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Cluster Of Differentiation 56 (CD56) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 84-103 89
EDTA plasma(n=5) 83-97 88
heparin plasma(n=5) 97-105 101
sodium citrate plasma(n=5) 97-105 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cluster Of Differentiation 56 (CD56) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cluster Of Differentiation 56 (CD56) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cluster Of Differentiation 56 (CD56) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-89% 94-103% 79-103% 89-101%
EDTA plasma(n=5) 83-103% 83-101% 86-105% 91-102%
heparin plasma(n=5) 92-104% 87-101% 81-92% 92-99%
sodium citrate plasma(n=5) 94-101% 80-98% 84-98% 85-99%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:CD56) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Medicine (Baltimore) Rapid detection of urinary soluble intercellular adhesion molecule-1 for determination of lupus nephritis activity Pubmed:29953010
OMICS Identification of a Novel Splice Variant of Neural Cell Adhesion Molecule in Glioblastoma Through Proteogenomics Analysis Pubmed:29927716
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB225Hu01 Recombinant Cluster Of Differentiation 56 (CD56) Positive Control; Immunogen; SDS-PAGE; WB.
APB225Hu61 Active Cluster Of Differentiation 56 (CD56) Cell culture; Activity Assays.
APB225Hu62 Active Cluster Of Differentiation 56 (CD56) Cell culture; Activity Assays.
EPB225Hu62 Eukaryotic Cluster Of Differentiation 56 (CD56) Positive Control; Immunogen; SDS-PAGE; WB.
EPB225Hu61 Eukaryotic Cluster Of Differentiation 56 (CD56) Positive Control; Immunogen; SDS-PAGE; WB.
PAB225Hu01 Polyclonal Antibody to Cluster Of Differentiation 56 (CD56) WB; IHC; ICC; IP.
MAB225Hu24 Monoclonal Antibody to Cluster Of Differentiation 56 (CD56) WB; IHC; ICC; IP.
MAB225Hu25 Monoclonal Antibody to Cluster Of Differentiation 56 (CD56) WB; IHC; ICC; IP.
MAB225Hu22 Monoclonal Antibody to Cluster Of Differentiation 56 (CD56) WB; IHC; ICC; IP.
MAB225Hu21 Monoclonal Antibody to Cluster Of Differentiation 56 (CD56) WB; IHC; ICC; IP.
MAB225Hu27 Monoclonal Antibody to Cluster Of Differentiation 56 (CD56) WB; IHC; ICC; IP.
MAB225Hu23 Monoclonal Antibody to Cluster Of Differentiation 56 (CD56) WB; IHC; ICC; IP.
MAB225Hu26 Monoclonal Antibody to Cluster Of Differentiation 56 (CD56) WB; IHC; ICC; IP.
RAB225Hu21 Recombinant Antibody to Cluster Of Differentiation 56 (CD56) WB; IF; ICC; IHC; IP; FCM.
FAB225Hu82 FITC-Linked Anti-Cluster Of Differentiation 56 (CD56) Monoclonal Antibody Flow cytometry.
SEB225Hu ELISA Kit for Cluster Of Differentiation 56 (CD56) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB225Hu Magnetic Luminex Assay Kit for Cluster Of Differentiation 56 (CD56) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기