SKU(재고 관리 코드):LMB820Ra
Magnetic Luminex Assay Kit for Troponin T (TNT) ,etc.
Magnetic Luminex Assay Kit for Troponin T (TNT) ,etc.
Product No.
LMB820Ra
Organism Species
Rattus norvegicus (Rat).
Sample Type
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.98-1000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.327 pg/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Troponin T (TNT) ,etc..
No significant cross-reactivity or interference between Troponin T (TNT) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Troponin T (TNT) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Troponin T (TNT) ,etc. in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 93-105 | 101 |
EDTA plasma(n=5) | 90-101 | 94 |
heparin plasma(n=5) | 85-95 | 90 |
sodium citrate plasma(n=5) | 95-102 | 98 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Troponin T (TNT) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Troponin T (TNT) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Troponin T (TNT) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 79-99% | 97-105% | 79-96% | 96-105% |
EDTA plasma(n=5) | 98-105% | 79-95% | 79-104% | 80-101% |
heparin plasma(n=5) | 80-104% | 88-98% | 93-101% | 92-101% |
sodium citrate plasma(n=5) | 80-104% | 89-97% | 92-99% | 86-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:TNT) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
Magazine | Citations |
IJC Heart & Vasculature | Cardiovascular changes in patients with non-severe Plasmodium vivax malaria article:S2352-9067(16)30010-0 |
Journal of the American Heart Association | Postinfarction Hearts Are Protected by Premature Senescent Cardiomyocytes Via GATA 4‐Dependent CCN 1 Secretion |
Experimental Gerontology | Neural control of postural sway: relationship to strength measures in young and elderly adults Pubmed: 30630036 |
Nature Communications | Preclinical development of a miR-132 inhibitor for heart failure treatment Pubmed: 32005803 |
Scientific Reports | Cardioprotective effect of grape polyphenol extract against doxorubicin induced cardiotoxicity Pubmed: 32895481 |
Molecular Medicine Reports | The mRNA expression of Il6 and Pdcd1 are predictive and protective factors for doxorubicin?induced cardiotoxicity 33300057 |
Cell Metabolism | Pharmacological inhibition of arachidonate 12-lipoxygenase ameliorates myocardial ischemia-reperfusion injury in multiple species 34536344 |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
SEB820Ra | ELISA Kit for Troponin T (TNT) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB820Ra | Magnetic Luminex Assay Kit for Troponin T (TNT) ,etc. | Magnetic Luminex Assay for Antigen Detection. |