제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMB820Mu

Magnetic Luminex Assay Kit for Troponin T (TNT) ,etc.

Magnetic Luminex Assay Kit for Troponin T (TNT) ,etc.

Detection range
Size
Sensitivity

Product No.

LMB820Mu

Organism Species

Mus musculus (Mouse).

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.98-1000pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.327 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Troponin T (TNT) ,etc..
No significant cross-reactivity or interference between Troponin T (TNT) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Troponin T (TNT) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Troponin T (TNT) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 99-105 102
EDTA plasma(n=5) 97-104 101
heparin plasma(n=5) 82-90 85
sodium citrate plasma(n=5) 84-97 92

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Troponin T (TNT) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Troponin T (TNT) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Troponin T (TNT) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 94-105% 96-104% 82-93% 79-96%
EDTA plasma(n=5) 78-90% 82-90% 80-94% 95-102%
heparin plasma(n=5) 94-104% 87-101% 84-101% 93-101%
sodium citrate plasma(n=5) 96-103% 82-103% 80-90% 80-91%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:TNT) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Magazine Citations
IJC Heart & Vasculature Cardiovascular changes in patients with non-severe Plasmodium vivax malaria article:S2352-9067(16)30010-0
Journal of the American Heart Association Postinfarction Hearts Are Protected by Premature Senescent Cardiomyocytes Via GATA 4‐Dependent CCN 1 Secretion
Experimental Gerontology Neural control of postural sway: relationship to strength measures in young and elderly adults Pubmed: 30630036
Nature Communications Preclinical development of a miR-132 inhibitor for heart failure treatment Pubmed: 32005803
Scientific Reports Cardioprotective effect of grape polyphenol extract against doxorubicin induced cardiotoxicity Pubmed: 32895481
Molecular Medicine Reports The mRNA expression of Il6 and Pdcd1 are predictive and protective factors for doxorubicin?induced cardiotoxicity 33300057
Cell Metabolism Pharmacological inhibition of arachidonate 12-lipoxygenase ameliorates myocardial ischemia-reperfusion injury in multiple species 34536344
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
SEB820Mu ELISA Kit for Troponin T (TNT) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB820Mu Magnetic Luminex Assay Kit for Troponin T (TNT) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기