제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMA480Ra

Magnetic Luminex Assay Kit for Myoglobin (MYO) ,etc.

Magnetic Luminex Assay Kit for Myoglobin (MYO) ,etc.

Detection range
Size
Sensitivity

Product No.

LMA480Ra

Organism Species

Rattus norvegicus (Rat).

Sample Type

Serum, plasma, tissue homogenates and other biological fluids.

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.04-40ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.013 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Myoglobin (MYO) ,etc..
No significant cross-reactivity or interference between Myoglobin (MYO) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Myoglobin (MYO) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Myoglobin (MYO) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 95-103 98
EDTA plasma(n=5) 86-95 91
heparin plasma(n=5) 78-103 95
sodium citrate plasma(n=5) 84-105 96

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Myoglobin (MYO) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Myoglobin (MYO) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Myoglobin (MYO) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 95-102% 80-96% 83-102% 93-101%
EDTA plasma(n=5) 79-101% 80-89% 95-102% 80-90%
heparin plasma(n=5) 78-101% 96-105% 84-92% 87-101%
sodium citrate plasma(n=5) 78-91% 93-105% 96-103% 90-99%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:MYO) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
European Journal of Applied Physiology Acute leukocyte, cytokine and adipocytokine responses to maximal and hypertrophic resistance exercise bouts Pubmed:25145982
International Journal of Molecular Sciences Transcriptional Alterations by Ischaemic Postconditioning in a Pig Infarction Model: Impact on Microvascular Protection Pubmed: 30650650
BIOSENS BIOELECTRON Electrochemical dual-aptamer-based biosensor for nonenzymatic detection of cardiac troponin I by nanohybrid electrocatalysts labeling combined with DNA … Pubmed: 30954926
Mikrochim Acta DNA nanotetrahedron linked dual-aptamer based voltammetric aptasensor for cardiac troponin I using a magnetic metal-organic framework as a label Pubmed: 31123904
ACS Appl Mater Interfaces Emitter–Quencher Pair of Single Atomic Co Sites and Monolayer Titanium Carbide MXenes for Luminol Chemiluminescent Reactions 34914377
Talanta A rapid fluorescent aptasensor for point-of-care detection of C-reactive protein Pubmed:35714415
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
NPA480Ra01 Native Myoglobin (MYO) Positive Control; Immunogen; SDS-PAGE; WB.
RPA480Ra01 Recombinant Myoglobin (MYO) Positive Control; Immunogen; SDS-PAGE; WB.
PAA480Ra01 Polyclonal Antibody to Myoglobin (MYO) WB; IHC; ICC; IP.
PAA480Ra02 Polyclonal Antibody to Myoglobin (MYO) WB; IHC; ICC; IP.
LAA480Ra81 FITC-Linked Polyclonal Antibody to Myoglobin (MYO) WB; IHC; ICC; IF.
LAA480Ra71 Biotin-Linked Polyclonal Antibody to Myoglobin (MYO) WB; IHC; ICC.
MAA480Ra21 Monoclonal Antibody to Myoglobin (MYO) WB; IHC; ICC; IP.
SEA480Ra ELISA Kit for Myoglobin (MYO) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA480Ra CLIA Kit for Myoglobin (MYO) Chemiluminescent immunoassay for Antigen Detection.
LMA480Ra Magnetic Luminex Assay Kit for Myoglobin (MYO) ,etc. Magnetic Luminex Assay for Antigen Detection.
KSA480Ra01 ELISA Kit DIY Materials for Myoglobin (MYO) Main materials for "Do It(ELISA Kit) Yourself"