SKU(재고 관리 코드):LMA480Mu
Magnetic Luminex Assay Kit for Myoglobin (MYO) ,etc.
Magnetic Luminex Assay Kit for Myoglobin (MYO) ,etc.
Product No.
LMA480Mu
Organism Species
Mus musculus (Mouse).
Sample Type
Serum, plasma, tissue homogenates and other biological fluids.
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
1.95-2000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.65 pg/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Myoglobin (MYO) ,etc..
No significant cross-reactivity or interference between Myoglobin (MYO) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Myoglobin (MYO) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Myoglobin (MYO) ,etc. in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 97-104 | 101 |
EDTA plasma(n=5) | 85-98 | 93 |
heparin plasma(n=5) | 96-104 | 101 |
sodium citrate plasma(n=5) | 78-90 | 86 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Myoglobin (MYO) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Myoglobin (MYO) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Myoglobin (MYO) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 85-101% | 82-101% | 86-94% | 93-101% |
EDTA plasma(n=5) | 97-105% | 94-102% | 95-103% | 81-95% |
heparin plasma(n=5) | 93-101% | 97-104% | 80-95% | 84-94% |
sodium citrate plasma(n=5) | 94-101% | 82-96% | 96-105% | 99-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:MYO) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
Magazine | Citations |
European Journal of Applied Physiology | Acute leukocyte, cytokine and adipocytokine responses to maximal and hypertrophic resistance exercise bouts Pubmed:25145982 |
International Journal of Molecular Sciences | Transcriptional Alterations by Ischaemic Postconditioning in a Pig Infarction Model: Impact on Microvascular Protection Pubmed: 30650650 |
BIOSENS BIOELECTRON | Electrochemical dual-aptamer-based biosensor for nonenzymatic detection of cardiac troponin I by nanohybrid electrocatalysts labeling combined with DNA … Pubmed: 30954926 |
Mikrochim Acta | DNA nanotetrahedron linked dual-aptamer based voltammetric aptasensor for cardiac troponin I using a magnetic metal-organic framework as a label Pubmed: 31123904 |
ACS Appl Mater Interfaces | Emitter–Quencher Pair of Single Atomic Co Sites and Monolayer Titanium Carbide MXenes for Luminol Chemiluminescent Reactions 34914377 |
Talanta | A rapid fluorescent aptasensor for point-of-care detection of C-reactive protein Pubmed:35714415 |
Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
RPA480Mu02 | Recombinant Myoglobin (MYO) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPA480Mu01 | Recombinant Myoglobin (MYO) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA480Mu02 | Polyclonal Antibody to Myoglobin (MYO) | WB; IHC; ICC; IP. |
PAA480Mu01 | Polyclonal Antibody to Myoglobin (MYO) | WB; IHC; ICC; IP. |
LAA480Mu81 | FITC-Linked Polyclonal Antibody to Myoglobin (MYO) | WB; IHC; ICC; IF. |
LAA480Mu71 | Biotin-Linked Polyclonal Antibody to Myoglobin (MYO) | WB; IHC; ICC. |
SEA480Mu | ELISA Kit for Myoglobin (MYO) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCA480Mu | CLIA Kit for Myoglobin (MYO) | Chemiluminescent immunoassay for Antigen Detection. |
LMA480Mu | Magnetic Luminex Assay Kit for Myoglobin (MYO) ,etc. | Magnetic Luminex Assay for Antigen Detection. |