제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMA185Ge

Magnetic Luminex Assay Kit for Free Thyroxine (fT4) ,etc.

Magnetic Luminex Assay Kit for Free Thyroxine (fT4) ,etc.

Detection range
Size
Sensitivity

Product No.

LMA185Ge

Organism Species

Pan-species (General).

Sample Type

serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Test Method

Competitive Inhibition

Assay Length

1.5h

Detection Range

0.09-90pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.03 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Free Thyroxine (fT4) ,etc..
No significant cross-reactivity or interference between Free Thyroxine (fT4) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Free Thyroxine (fT4) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Free Thyroxine (fT4) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-93 90
EDTA plasma(n=5) 91-98 94
heparin plasma(n=5) 93-105 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Free Thyroxine (fT4) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Free Thyroxine (fT4) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Free Thyroxine (fT4) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 91-98% 78-96% 78-97% 97-105%
EDTA plasma(n=5) 92-105% 80-104% 95-102% 88-102%
heparin plasma(n=5) 98-105% 80-97% 87-101% 91-99%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:fT4) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

     

    Magazine Citations
    Frontiers in cellular neuroscience Elevated Thyroid Peroxidase Antibody Increases Risk of Post-partum Depression by Decreasing Prefrontal Cortex BDNF and 5-HT Levels in Mice pubmed:28119573
    ARC Journal of Nutrition and Growth Effect of Selenium and Zinc Supplementation on Hypothyroidism in Rats ISSN 2455-2550
    Frontiers in Neuroscience Modulation of Calcitonin, Parathyroid Hormone, and Thyroid Hormone Secretion by Electrical Stimulation of Sympathetic and Parasympathetic Nerves in Anesthetized Rats. pubmed:28713236
    Brain Research Age-Dependent Evaluation of Long-Term Depression Responses in Hyperthyroid Rats: Possible Roles of Oxidative Intracellular Redox Status Pubmed: 31288003
    Journal of Physiological Sciences Thyroxin and calcitonin secretion into thyroid venous blood is regulated by pharyngeal mechanical stimulation in anesthetized rats Pubmed: 31270742
    International Journal of Clinical and Experimental Medicine Apatinib inhibits proliferation of different lung cancer cells in vitro and in vivo by promoting apoptosis and inducing cell cycle arrest
    Int J Dev Neurosci Effect of L©\thyroxine administration on long©\term potentiation and accompanying mitogen©\activated protein kinases in rats 33576121
    Catalog No. Related products for research use of Pan-species (General) Organism species Applications (RESEARCH USE ONLY!)
    IEA185Ge Instant ELISA Kit for Free Thyroxine (fT4) Enzyme-linked immunosorbent assay for Antigen Detection.
    CEA185Ge ELISA Kit for Free Thyroxine (fT4) Enzyme-linked immunosorbent assay for Antigen Detection.
    CCA185Ge CLIA Kit for Free Thyroxine (fT4) Chemiluminescent immunoassay for Antigen Detection.
    LMA185Ge Magnetic Luminex Assay Kit for Free Thyroxine (fT4) ,etc. Magnetic Luminex Assay for Antigen Detection.
    전체 세부 정보 보기