제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMC312Hu

Magnetic Luminex Assay Kit for Angiotensin III (AngIII) ,etc.

Magnetic Luminex Assay Kit for Angiotensin III (AngIII) ,etc.

Detection range
Size
Sensitivity

Product No.

LMC312Hu

Organism Species

Homo sapiens (Human).

Sample Type

serum, plasma and other biological fluids

Test Method

Competitive Inhibition

Assay Length

1.5h

Detection Range

0.1-100pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.033 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Angiotensin III (AngIII) ,etc..
No significant cross-reactivity or interference between Angiotensin III (AngIII) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Angiotensin III (AngIII) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Angiotensin III (AngIII) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 82-95 91
EDTA plasma(n=5) 94-102 97
heparin plasma(n=5) 90-103 94

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Angiotensin III (AngIII) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Angiotensin III (AngIII) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Angiotensin III (AngIII) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-101% 94-103% 99-105% 78-89%
EDTA plasma(n=5) 93-102% 89-97% 80-89% 87-95%
heparin plasma(n=5) 96-104% 83-96% 94-101% 79-96%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:AngIII) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine. 

     

    Magazine Citations
    Mol Pain Mechanisms underlying clinical efficacy of Angiotensin II type 2 receptor (AT2R) antagonist EMA401 in neuropathic pain: clinical tissue and in vitro studies PubMed: 26111701
    Journal of Atherosclerosis and Thrombosis Involvement of Angiotensin II Type 1 and 2 Receptors in Gelatinase ReCavia (Guinea pig )lation in Human Carotid Atheroma in vitro Pubmed:26947595
    Dikkat Eksikliği Hiperaktivite Bozukluğu Tanısı Olan Anjiyotensin I, II, III, Alamandin peptid, Anjiyotensin Dönüştürücü Enzim (ACE), NADPH Oksidaz Enzim Serum …
    Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
    PAC312Hu01 Polyclonal Antibody to Angiotensin III (AngIII) WB; IHC; ICC; IP.
    LAC312Hu71 Biotin-Linked Polyclonal Antibody to Angiotensin III (AngIII) WB; IHC; ICC.
    CEC312Hu ELISA Kit for Angiotensin III (AngIII) Enzyme-linked immunosorbent assay for Antigen Detection.
    LMC312Hu Magnetic Luminex Assay Kit for Angiotensin III (AngIII) ,etc. Magnetic Luminex Assay for Antigen Detection.
    KSC312Hu11 ELISA Kit DIY Materials for Angiotensin III (AngIII) Main materials for "Do It (ELISA Kit) Yourself".