제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LME592Hu

Magnetic Luminex Assay Kit for Ubiquitin A 52 Residue Ribosomal Protein Fusion Product 1 (UBA52) ,etc.

Magnetic Luminex Assay Kit for Ubiquitin A 52 Residue Ribosomal Protein Fusion Product 1 (UBA52) ,etc.

Detection range
Size
Sensitivity

Product No.

LME592Hu

Organism Species

Homo sapiens (Human).

Sample Type

Tissue homogenates and other biological fluids.

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.02-20ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.007 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Ubiquitin A 52 Residue Ribosomal Protein Fusion Product 1 (UBA52) ,etc..
No significant cross-reactivity or interference between Ubiquitin A 52 Residue Ribosomal Protein Fusion Product 1 (UBA52) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Ubiquitin A 52 Residue Ribosomal Protein Fusion Product 1 (UBA52) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Ubiquitin A 52 Residue Ribosomal Protein Fusion Product 1 (UBA52) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 88-102 97
EDTA plasma(n=5) 89-105 98
heparin plasma(n=5) 78-105 97
sodium citrate plasma(n=5) 91-102 96

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ubiquitin A 52 Residue Ribosomal Protein Fusion Product 1 (UBA52) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ubiquitin A 52 Residue Ribosomal Protein Fusion Product 1 (UBA52) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Ubiquitin A 52 Residue Ribosomal Protein Fusion Product 1 (UBA52) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 91-98% 80-92% 78-104% 89-103%
EDTA plasma(n=5) 88-104% 90-104% 82-99% 97-105%
heparin plasma(n=5) 91-104% 91-102% 80-93% 80-90%
sodium citrate plasma(n=5) 95-105% 94-102% 88-102% 94-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:UBA52) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPE592Hu01 Recombinant Ubiquitin A 52 Residue Ribosomal Protein Fusion Product 1 (UBA52) Positive Control; Immunogen; SDS-PAGE; WB.
PAE592Hu01 Polyclonal Antibody to Ubiquitin A 52 Residue Ribosomal Protein Fusion Product 1 (UBA52) WB; IHC; ICC; IP.
MAE592Hu21 Monoclonal Antibody to Ubiquitin A 52 Residue Ribosomal Protein Fusion Product 1 (UBA52) WB; IHC; ICC; IP.
SEE592Hu ELISA Kit for Ubiquitin A 52 Residue Ribosomal Protein Fusion Product 1 (UBA52) Enzyme-linked immunosorbent assay for Antigen Detection.
LME592Hu Magnetic Luminex Assay Kit for Ubiquitin A 52 Residue Ribosomal Protein Fusion Product 1 (UBA52) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기