Cloud-clone

SKU(재고 관리 코드):LMG515Hu

Magnetic Luminex Assay Kit for Chymase 1, Mast Cell (CMA1) ,etc.

Magnetic Luminex Assay Kit for Chymase 1, Mast Cell (CMA1) ,etc.

Detection range
Size
Sensitivity

Product No.

LMG515Hu

Organism Species

Homo sapiens (Human).

Sample Type

Serum, plasma, tissue homogenates, cell lysates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

1.95-2000pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.65 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Chymase 1, Mast Cell (CMA1) ,etc..
No significant cross-reactivity or interference between Chymase 1, Mast Cell (CMA1) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Chymase 1, Mast Cell (CMA1) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Chymase 1, Mast Cell (CMA1) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 82-91 85
EDTA plasma(n=5) 78-99 94
heparin plasma(n=5) 88-99 92
sodium citrate plasma(n=5) 84-96 90

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Chymase 1, Mast Cell (CMA1) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Chymase 1, Mast Cell (CMA1) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Chymase 1, Mast Cell (CMA1) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 96-103% 85-101% 80-88% 82-92%
EDTA plasma(n=5) 96-104% 89-103% 79-104% 98-105%
heparin plasma(n=5) 94-101% 86-101% 78-102% 84-101%
sodium citrate plasma(n=5) 87-95% 88-95% 85-102% 82-98%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:CMA1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Pathobiology Anti-Angiotensin and Hypoglycemic Treatments Suppress Liver Metastasis of Colon Cancer Cells Karger: 000330169
Clinical and Experimental Metastasis Diabetes-associated angiotensin activation enhances liver metastasis of colon cancer PubMed: 22552372
Mediators of Inflammation Mediators of Mast Cells in Bullous Pemphigoid and Dermatitis Herpetiformis Pubmed:25400334
Neurogastroenterology &amp; Motility Peritoneal mast cell degranulation and gastrointestinal recovery in patients undergoing colorectal surgery Pubmed:25677271
IJC Metab Endocr The autocrine role of tryptase in pressure overload-induced mast cell activation, chymase release and cardiac fibrosis PubMed: 26722642
Journal of Neuroinflammation Oral sensitization to whey proteins induces age-and sex-dependent behavioral abnormality and neuroinflammatory responses in a mouse model of food … Pubmed:29685134
Revista do Instituto de Medicina Tropical de São Paulo Vasoactive intestinal peptide degradation might influence Interleukin-17 expression in cardiac chagasic patients Pubmed: 30365640
Science Advances Platelets trigger perivascular mast cell degranulation to cause inflammatory responses and tissue injury Pubmed: 32206714
Immunity Inflammation and Disease Disruption in the balance between apolipoprotein A‐I and mast cell chymase in chronic hypersensitivity pneumonitis Pubmed: 33016012
Microbiol Spectr Mast Cell-Derived Proteases Induce Endothelial Permeability and Vascular Damage in Severe Fever with Thrombocytopenia Syndrome Pubmed:35612327
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPG515Hu01 Recombinant Chymase 1, Mast Cell (CMA1) Positive Control; Immunogen; SDS-PAGE; WB.
PAG515Hu01 Polyclonal Antibody to Chymase 1, Mast Cell (CMA1) WB; IHC; ICC; IP.
PAG515Hu02 Polyclonal Antibody to Chymase 1, Mast Cell (CMA1) WB; IHC; ICC; IP.
MAG515Hu21 Monoclonal Antibody to Chymase 1, Mast Cell (CMA1) WB; IHC; ICC; IP.
SEG515Hu ELISA Kit for Chymase 1, Mast Cell (CMA1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMG515Hu Magnetic Luminex Assay Kit for Chymase 1, Mast Cell (CMA1) ,etc. Magnetic Luminex Assay for Antigen Detection.