SKU(재고 관리 코드):LMA321Mu

Magnetic Luminex Assay Kit for Galectin 1 (GAL1) ,etc.

Magnetic Luminex Assay Kit for Galectin 1 (GAL1) ,etc.

Detection range
Size
Sensitivity

Product No.

LMA321Mu

Organism Species

Mus musculus (Mouse).

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.01-10ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.003 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Galectin 1 (GAL1) ,etc..
No significant cross-reactivity or interference between Galectin 1 (GAL1) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Galectin 1 (GAL1) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Galectin 1 (GAL1) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-88 80
EDTA plasma(n=5) 93-101 96
heparin plasma(n=5) 86-101 92

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Galectin 1 (GAL1) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Galectin 1 (GAL1) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Galectin 1 (GAL1) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-98% 86-101% 98-105% 87-101%
EDTA plasma(n=5) 79-89% 95-102% 99-105% 81-92%
heparin plasma(n=5) 89-104% 92-101% 94-102% 89-96%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:GAL1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
International Journal of Oncology Galectin-1-mediated cell adhesion, invasion and cell death in human anaplastic large cell lymphoma: Regulatory roles of cell surface glycans Pubmed:24589677
Clinica Chimica Acta Galectin-1 and galectin-3: plausible tumour markers for oral squamous cell carcinoma and suitable targets for screening high-risk population Pubmed:25578395
Journal of Perinatal Medicine Cord blood galectin-1 and-3 concentrations in term pregnancies with normal restricted and increased fetal growth PubMed: 24717333
Biomaterials Noninvasive small-animal imaging of galectin-1 upregulation for predicting tumor resistance to radiotherapy Pubmed:29272764
Advances in Experimental Medicine and Biology Molecules of Damage-Associated Patterns in Bronchoalveolar Lavage Fluid and Serum in Chronic Obstructive Pulmonary Disease Pubmed:29429028
RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY Elevated level of Galectin-1 in bronchoalveolar lavage of patients with idiopathic pulmonary fibrosis Pubmed: 31678459
Eur J Nucl Med Mol Imaging Galectin expression detected by 68Ga-galectracer PET as a predictive biomarker of radiotherapy resistance Pubmed:35106644
Medicine Regulatory T cells, damage-associated molecular patterns, and myeloid-derived suppressor cells in bronchoalveolar lavage fluid interlinked with chronic obstructive … Pubmed:35687771
In Vitro Bovine Embryo Production Using Medium's Supplemented with Recombinant Human Galectin-1 Buffered
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPA321Mu01 Recombinant Galectin 1 (GAL1) Positive Control; Immunogen; SDS-PAGE; WB.
RPA321Mu02 Recombinant Galectin 1 (GAL1) Positive Control; Immunogen; SDS-PAGE; WB.
PAA321Mu02 Polyclonal Antibody to Galectin 1 (GAL1) WB; IHC; ICC; IP.
PAA321Mu01 Polyclonal Antibody to Galectin 1 (GAL1) WB; IHC; ICC; IP.
LAA321Mu71 Biotin-Linked Polyclonal Antibody to Galectin 1 (GAL1) WB; IHC; ICC.
LAA321Mu81 FITC-Linked Polyclonal Antibody to Galectin 1 (GAL1) WB; IHC; ICC; IF.
SEA321Mu ELISA Kit for Galectin 1 (GAL1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA321Mu Magnetic Luminex Assay Kit for Galectin 1 (GAL1) ,etc. Magnetic Luminex Assay for Antigen Detection.
KSA321Mu01 ELISA Kit DIY Materials for Galectin 1 (GAL1) Main materials for "Do It (ELISA Kit) Yourself".