제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMA308Bo

Magnetic Luminex Assay Kit for Galectin 8 (GAL8) ,etc.

Magnetic Luminex Assay Kit for Galectin 8 (GAL8) ,etc.

Detection range
Size
Sensitivity

Product No.

LMA308Bo

Organism Species

Bos taurus; Bovine (Cattle).

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.02-20ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.007 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Galectin 8 (GAL8) ,etc..
No significant cross-reactivity or interference between Galectin 8 (GAL8) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Galectin 8 (GAL8) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Galectin 8 (GAL8) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-95 82
EDTA plasma(n=5) 79-89 85
heparin plasma(n=5) 93-101 96

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Galectin 8 (GAL8) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Galectin 8 (GAL8) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Galectin 8 (GAL8) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 92-101% 84-96% 91-99% 80-102%
EDTA plasma(n=5) 80-102% 81-92% 86-98% 81-105%
heparin plasma(n=5) 78-98% 78-96% 88-102% 89-96%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:GAL8) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Cell Metabolism Podoplanin-Expressing Macrophages Promote Lymphangiogenesis and Lymphoinvasion in Breast Cancer Pubmed: 31447322
CALCIFIED TISSUE INTERNATIONAL The Dysregulated Galectin Network Activates NF-κB to Induce Disease Markers and Matrix Degeneration in 3D Pellet Cultures of Osteoarthritic Chondrocytes Pubmed: 33185768
Catalog No. Related products for research use of Bos taurus; Bovine (Cattle) Organism species Applications (RESEARCH USE ONLY!)
RPA308Bo01 Recombinant Galectin 8 (GAL8) Positive Control; Immunogen; SDS-PAGE; WB.
APA308Bo01 Active Galectin 8 (GAL8) Cell culture; Activity Assays.
PAA308Bo01 Polyclonal Antibody to Galectin 8 (GAL8) WB; IHC; ICC; IP.
MAA308Bo21 Monoclonal Antibody to Galectin 8 (GAL8) WB; IHC; ICC; IP.
SEA308Bo ELISA Kit for Galectin 8 (GAL8) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA308Bo Magnetic Luminex Assay Kit for Galectin 8 (GAL8) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기