제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMA117Ra

Magnetic Luminex Assay Kit for Superoxide Dismutase 3, Extracellular (SOD3) ,etc.

Magnetic Luminex Assay Kit for Superoxide Dismutase 3, Extracellular (SOD3) ,etc.

Detection range
Size
Sensitivity

Product No.

LMA117Ra

Organism Species

Rattus norvegicus (Rat).

Sample Type

serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.05-50ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.017 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Superoxide Dismutase 3, Extracellular (SOD3) ,etc..
No significant cross-reactivity or interference between Superoxide Dismutase 3, Extracellular (SOD3) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Superoxide Dismutase 3, Extracellular (SOD3) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Superoxide Dismutase 3, Extracellular (SOD3) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 92-103 95
EDTA plasma(n=5) 78-104 88
heparin plasma(n=5) 84-97 94

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Superoxide Dismutase 3, Extracellular (SOD3) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Superoxide Dismutase 3, Extracellular (SOD3) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Superoxide Dismutase 3, Extracellular (SOD3) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-89% 82-95% 78-101% 83-98%
EDTA plasma(n=5) 80-97% 95-103% 79-98% 83-98%
heparin plasma(n=5) 82-91% 97-105% 93-101% 88-95%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:SOD3) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Current Alzheimer Research Comparison of Extracellular and Intracellular Blood Compartments Highlights Redox Alterations in Alzheimer's and Mild Cognitive Impairment Patients. pubmed:27748187
Frontiers in Microbiology Burn Serum Increases Staphylococcus aureus Biofilm Formation via Oxidative Stress. pubmed:28702016
Nature Communications SOD3 improves the tumor response to chemotherapy by stabilizing endothelial HIF-2α Pubmed:29422508
BMC Neuroscience Neuroprotective dobutamine treatment upregulates superoxide dismutase 3, anti-oxidant and survival genes and attenuates genes mediating inflammation Pubmed:29523072
Diabetes-Metabolism Research and Reviews Myeloperoxidase, superoxide dismutase‐3, cardiometabolic risk factors, and distal sensorimotor polyneuropathy: The KORA F4/FF4 study Pubmed:29577557
Advances in Medical Sciences Selected elements of extracellular matrix of the skin in diabetes and insulin resistance Pubmed: 31146169
Clinical Kidney Journal Serum uromodulin is inversely associated with biomarkers of subclinical inflammation in the population-based KORA F4 study
PLoS One Association of circulating MR-proADM with all-cause and cardiovascular mortality in the general population: Results from the KORA F4 cohort study Pubmed:34990470
ORIGINAL RESEARCH PATHOPHYSIOLOGY EFFECTS OF HIS-PHE-ARG-TRP-PRO-GLY-PRO PEPTIDE ON FREE-RADICAL OXIDATION PROCESSES IN CONDITIONS OF CHRONIC RESTRAINT …
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPA117Ra01 Recombinant Superoxide Dismutase 3, Extracellular (SOD3) Positive Control; Immunogen; SDS-PAGE; WB.
PAA117Ra01 Polyclonal Antibody to Superoxide Dismutase 3, Extracellular (SOD3) WB; IHC; ICC; IP.
MAA117Ra21 Monoclonal Antibody to Superoxide Dismutase 3, Extracellular (SOD3) WB; IHC; ICC; IP.
SEA117Ra ELISA Kit for Superoxide Dismutase 3, Extracellular (SOD3) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA117Ra Magnetic Luminex Assay Kit for Superoxide Dismutase 3, Extracellular (SOD3) ,etc. Magnetic Luminex Assay for Antigen Detection.
KSA117Ra01 ELISA Kit DIY Materials for Superoxide Dismutase 3, Extracellular (SOD3) Main materials for "Do It (ELISA Kit) Yourself".
전체 세부 정보 보기