Magnetic Luminex Assay Kit for Motilin (MTL) ,etc.
Magnetic Luminex Assay Kit for Motilin (MTL) ,etc.
Product No.
LMA575Ra
Organism Species
Rattus norvegicus (Rat).
Sample Type
Serum, plasma and other biological fluids
Test Method
Competitive Inhibition
Assay Length
1.5h
Detection Range
5.86-6000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 1.953 pg/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Motilin (MTL) ,etc..
No significant cross-reactivity or interference between Motilin (MTL) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Motilin (MTL) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Motilin (MTL) ,etc. in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 79-93 | 88 |
EDTA plasma(n=5) | 98-105 | 101 |
heparin plasma(n=5) | 93-101 | 97 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Motilin (MTL) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Motilin (MTL) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Motilin (MTL) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 78-98% | 86-101% | 93-104% | 89-101% |
EDTA plasma(n=5) | 86-103% | 79-95% | 84-95% | 93-105% |
heparin plasma(n=5) | 90-98% | 88-101% | 80-95% | 82-91% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:MTL) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
Magazine | Citations |
世界华人消化杂志 | 清醒状态下热射病大鼠胃肠动力与胃泌素、胃动素的变化 Wjgnet:Source |
Sci Rep. | Using the "target constituent removal combined with bioactivity assay" strategy to investigate the optimum arecoline content in charred areca nut. pubmed:28054652 |
Applied Biological Chemistry | Positive enhancement of Lactobacillus fermentum HY01 on intestinal movements of mice having constipation 10.1007/s13765-017-0327-3 |
Biomed Research International | Colonic Transit Time and Gut Peptides in Adult Patients with Slow and Normal Colonic Transit Constipation pubmed:29082242 |
Evidence-Based Complementary and Alternative Medicine | Home-Based Transcutaneous Neuromodulation Improved Constipation via Modulating Gastrointestinal Hormones and Bile Acids Pubmed:29853946 |
The American Journal of the Medical Sciences | The Relations Among Serum Ghrelin, Motilin and Gastric Emptying and Autonomic Function in Autoimmune Gastritis Pubmed:29753372 |
NEUROGASTROENTEROLOGY AND MOTILITY | Integrative effects of transcutaneous electrical acustimulation on abdominal pain, gastrointestinal motility, and inflammation in patients with early‐stage acute … 34536258 |
Evid Based Complement Alternat Med | The Inhibitory Effects of Naringin in a Rat Model of Postoperative Intraperitoneal Adhesion Formation Pubmed:35069760 |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
RPA575Ra01 | Recombinant Motilin (MTL) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA575Ra01 | Polyclonal Antibody to Motilin (MTL) | WB; IHC; ICC; IP. |
MAA575Ra21 | Monoclonal Antibody to Motilin (MTL) | WB; IHC; ICC; IP. |
CEA575Ra | ELISA Kit for Motilin (MTL) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA575Ra | Magnetic Luminex Assay Kit for Motilin (MTL) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
KSA575Ra11 | ELISA Kit DIY Materials for Motilin (MTL) | Main materials for "Do It (ELISA Kit) Yourself". |