제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMC750Hu

Magnetic Luminex Assay Kit for Phenylalanine Hydroxylase (PAH) ,etc.

Magnetic Luminex Assay Kit for Phenylalanine Hydroxylase (PAH) ,etc.

Detection range
Size
Sensitivity

Product No.

LMC750Hu

Organism Species

Homo sapiens (Human).

Sample Type

Tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.1-100ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.033 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Phenylalanine Hydroxylase (PAH) ,etc..
No significant cross-reactivity or interference between Phenylalanine Hydroxylase (PAH) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Phenylalanine Hydroxylase (PAH) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Phenylalanine Hydroxylase (PAH) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 96-105 101
EDTA plasma(n=5) 81-90 86
heparin plasma(n=5) 88-103 91

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Phenylalanine Hydroxylase (PAH) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Phenylalanine Hydroxylase (PAH) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Phenylalanine Hydroxylase (PAH) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 80-101% 81-102% 86-103%
EDTA plasma(n=5) 78-103% 94-101% 83-97% 88-97%
heparin plasma(n=5) 93-105% 91-104% 87-95% 96-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:PAH) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPC750Hu02 Recombinant Phenylalanine Hydroxylase (PAH) Positive Control; Immunogen; SDS-PAGE; WB.
RPC750Hu01 Recombinant Phenylalanine Hydroxylase (PAH) Positive Control; Immunogen; SDS-PAGE; WB.
PAC750Hu01 Polyclonal Antibody to Phenylalanine Hydroxylase (PAH) WB,IHC
PAC750Hu02 Polyclonal Antibody to Phenylalanine Hydroxylase (PAH) WB; IHC; ICC; IP.
LAC750Hu71 Biotin-Linked Polyclonal Antibody to Phenylalanine Hydroxylase (PAH) WB; IHC; ICC.
MAC750Hu21 Monoclonal Antibody to Phenylalanine Hydroxylase (PAH) WB; IHC; ICC; IP.
MAC750Hu23 Monoclonal Antibody to Phenylalanine Hydroxylase (PAH) WB; IHC; ICC; IP.
MAC750Hu22 Monoclonal Antibody to Phenylalanine Hydroxylase (PAH) WB; IHC; ICC; IP.
MAC750Hu24 Monoclonal Antibody to Phenylalanine Hydroxylase (PAH) WB; IHC; ICC; IP.
MAC750Hu25 Monoclonal Antibody to Phenylalanine Hydroxylase (PAH) WB; IHC; ICC; IP.
SEC750Hu ELISA Kit for Phenylalanine Hydroxylase (PAH) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC750Hu Magnetic Luminex Assay Kit for Phenylalanine Hydroxylase (PAH) ,etc. Magnetic Luminex Assay for Antigen Detection.
KSC750Hu01 ELISA Kit DIY Materials for Phenylalanine Hydroxylase (PAH) Main materials for "Do It (ELISA Kit) Yourself".
전체 세부 정보 보기