제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMA950Mu

Magnetic Luminex Assay Kit for Von Willebrand Factor Cleaving Protease (vWFCP) ,etc.

Magnetic Luminex Assay Kit for Von Willebrand Factor Cleaving Protease (vWFCP) ,etc.

Detection range
Size
Sensitivity

Product No.

LMA950Mu

Organism Species

Mus musculus (Mouse).

Sample Type

Serum, plasma, tissue homogenates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

1.95-2000pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.65 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Von Willebrand Factor Cleaving Protease (vWFCP) ,etc..
No significant cross-reactivity or interference between Von Willebrand Factor Cleaving Protease (vWFCP) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Von Willebrand Factor Cleaving Protease (vWFCP) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Von Willebrand Factor Cleaving Protease (vWFCP) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 86-104 92
EDTA plasma(n=5) 85-94 88
heparin plasma(n=5) 80-97 87
sodium citrate plasma(n=5) 97-105 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Von Willebrand Factor Cleaving Protease (vWFCP) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Von Willebrand Factor Cleaving Protease (vWFCP) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Von Willebrand Factor Cleaving Protease (vWFCP) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 86-103% 79-96% 78-101% 95-102%
EDTA plasma(n=5) 78-97% 93-101% 78-95% 80-92%
heparin plasma(n=5) 98-105% 96-105% 79-97% 95-105%
sodium citrate plasma(n=5) 97-105% 82-97% 87-101% 79-96%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:vWFCP) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
33 Neutrophil Protease Cleavage of Von Willebrand Factor in Glomeruli - An Anti-thrombotic Mechanism in the Kidney. pubmed:28139439
Experimental and Therapeutic Medicine Risk stratification and prognostic evaluation of endothelial cell‑specific molecule1, von Willebrand factor, and a disintegrin‑like and metalloprotease with …
Scientific Reports Association between Upper-airway Surgery and Ameliorative Risk Markers of endothelial function in obstructive Sleep Apnea Pubmed: 31882827
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
SEA950Mu ELISA Kit for Von Willebrand Factor Cleaving Protease (vWFCP) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA950Mu Magnetic Luminex Assay Kit for Von Willebrand Factor Cleaving Protease (vWFCP) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기