SKU(재고 관리 코드):LMC992Hu
Magnetic Luminex Assay Kit for Glutathione Peroxidase 3, Plasma (GPX3) ,etc.
Magnetic Luminex Assay Kit for Glutathione Peroxidase 3, Plasma (GPX3) ,etc.
Product No.
LMC992Hu
Organism Species
Homo sapiens (Human).
Sample Type
serum, plasma, breast milk and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.1-100ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.033 ng/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Glutathione Peroxidase 3, Plasma (GPX3) ,etc..
No significant cross-reactivity or interference between Glutathione Peroxidase 3, Plasma (GPX3) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Glutathione Peroxidase 3, Plasma (GPX3) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Glutathione Peroxidase 3, Plasma (GPX3) ,etc. in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 95-103 | 98 |
EDTA plasma(n=5) | 89-101 | 94 |
heparin plasma(n=5) | 83-92 | 86 |
sodium citrate plasma(n=5) | 82-98 | 86 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glutathione Peroxidase 3, Plasma (GPX3) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glutathione Peroxidase 3, Plasma (GPX3) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glutathione Peroxidase 3, Plasma (GPX3) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 80-101% | 93-102% | 79-104% | 89-96% |
EDTA plasma(n=5) | 78-89% | 82-92% | 81-101% | 80-95% |
heparin plasma(n=5) | 93-105% | 90-98% | 84-97% | 80-90% |
sodium citrate plasma(n=5) | 90-99% | 83-97% | 83-99% | 78-104% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:GPX3) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
Magazine | Citations |
Reproduction | Alteration in the intrafollicular thiol–redox system in infertile women with endometriosis Pubmed:25376627 |
international journal of cardiology | Endothelial function impairment in STEMI patients with out-of-hospital cardiac arrest under therapeutic hypothermia treatment. pubmed:28087172 |
Current Alzheimer Research | Comparison of Extracellular and Intracellular Blood Compartments Highlights Redox Alterations in Alzheimer's and Mild Cognitive Impairment Patients. pubmed:27748187 |
Frontiers in Microbiology | Burn Serum Increases Staphylococcus aureus Biofilm Formation via Oxidative Stress. pubmed:28702016 |
Clinical and Translational Oncology | Hydrogen peroxide-induced mitophagy contributes to laryngeal cancer cells survival via the upregulation of FUNDC1 Pubmed: 30284230 |
Toxicological Sciences | Kidney toxicity and response of selenium containing protein-glutathione peroxidase (Gpx3) to CdTe QDs on different levels Pubmed: 30535317 |
Available at SSRN 3234834 | Human Plasma Protein (s) Based Conceptual Diagnostic Tool for Altitude-Acclimation Assessment |
The Journal of Nutritional Biochemistry | Dietary selenium deficiency or selenomethionine excess drastically alters organ selenium contents without altering the expression of most selenoproteins in mice |
Ecotoxicology and Environmental Safety | Molecular mechanisms of lead-induced changes of selenium status in mice livers through interacting with selenoprotein P |
ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY | In vivo and in vitro studies on inactivation of selenium containing protein-glutathione peroxidase 3 in mice nephrocytes caused by lead Pubmed: 32678766 |
Nat Immunol | Selenium–GPX4 axis protects follicular helper T cells from ferroptosis 34413521 |
Eberhard Karls University | Experimental nephrotic syndrome in mice with an inducible deletion of podocin and the role of plasminogen in sodium retention |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
RPC992Hu02 | Recombinant Glutathione Peroxidase 3, Plasma (GPX3) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPC992Hu01 | Recombinant Glutathione Peroxidase 3, Plasma (GPX3) | Positive Control; Immunogen; SDS-PAGE; WB. |
EPC992Hu61 | Eukaryotic Glutathione Peroxidase 3, Plasma (GPX3) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAC992Hu01 | Polyclonal Antibody to Glutathione Peroxidase 3, Plasma (GPX3) | WB,IHC |
PAC992Hu02 | Polyclonal Antibody to Glutathione Peroxidase 3, Plasma (GPX3) | WB; IHC; ICC; IP. |
MAC992Hu22 | Monoclonal Antibody to Glutathione Peroxidase 3, Plasma (GPX3) | WB; IHC; ICC; IP. |
SEC992Hu | ELISA Kit for Glutathione Peroxidase 3, Plasma (GPX3) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMC992Hu | Magnetic Luminex Assay Kit for Glutathione Peroxidase 3, Plasma (GPX3) ,etc. | Magnetic Luminex Assay for Antigen Detection. |